Effective atomic number in the Rayleigh to Compton scattering ratio

被引:116
作者
Duvauchelle, P [1 ]
Peix, G [1 ]
Babot, D [1 ]
机构
[1] Inst Natl Sci Appl Lyon, Lab Controle Non Destruct Rayonnements Ionisants, F-69621 Villeurbanne, France
关键词
non-destructive testing; X-ray imaging; Rayleigh to Compton scattering ratio; effective atomic number; materials characterization;
D O I
10.1016/S0168-583X(99)00450-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 [仪器科学与技术]; 080401 [精密仪器及机械]; 081102 [检测技术与自动化装置];
摘要
Detection and counting X-ray photons scattered by the Rayleigh and Compton processes enable matter to be characterized locally. A theoretical relation was first established which simulates the result of a Rayleigh to Compton ratio measurement. It can thus be shown that a correct choice of scattering angle and photon energy enables a result to be obtained which is almost independent of X-ray attenuation inside the sample. With this condition, the Rayleigh to Compton scattering ratio depends only on the mixture under study and provides a local measurement of certain complicated functions of the atomic number Z and of the weight percentage of the different elements which constitute the compound. This function is usually called the "effective atomic number", Z(eff). Different methods of calculation of Z(eff) are found in the literature, four of them, those used most frequently, were tested. There is no unique relation between the computed Z(eff) and 80 experimental results performed on aqueous solutions with different concentrations of eight elements, having Z values ranging from 13 to 64. This observation led us to the conclusion that any effective atomic number is valid only for given experimental conditions. Finally, a new method of calculating Z(eff) was developed for the Rayleigh to Compton scattering ratio, which is applicable for any material, scattering angle or photon energy. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:221 / 228
页数:8
相关论文
共 15 条
[1]
Attix F.H., 1968, Radiation Dosimetry
[2]
Compressive deformation and yielding mechanisms in cellular Al alloys determined using X-ray tomography and surface strain mapping [J].
Bart-Smith, H ;
Bastawros, AF ;
Mumm, DR ;
Evans, AG ;
Sypeck, DJ ;
Wadley, HNG .
ACTA MATERIALIA, 1998, 46 (10) :3583-3592
[3]
GAMMA-RAY SCATTERING STUDIES OF COMPOSITION VARIATIONS IN ALLOYS [J].
COOPER, MJ ;
ROLLASON, AJ ;
TUXWORTH, RW .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1982, 15 (05) :568-572
[4]
X-RAY SCATTERING FACTORS COMPUTED FROM NUMERICAL HARTREE-FOCK WAVE FUNCTIONS [J].
CROMER, DT ;
MANN, JB .
ACTA CRYSTALLOGRAPHICA SECTION A-CRYSTAL PHYSICS DIFFRACTION THEORETICAL AND GENERAL CRYSTALLOGRAPHY, 1968, A 24 :321-&
[5]
DUVAUCHELLE P, 1998, TOMOGRAPHIE DIFFUSIO
[6]
FELDKAMP LA, 1989, J BONE MINER RES, V1, P3
[7]
A K edge filter technique for optimization of the coherent-to-Compton scatter ratio method [J].
Harding, G .
MEDICAL PHYSICS, 1995, 22 (12) :2007-2014
[8]
TOLERANCE DEVELOPMENT TO AROUSAL EFFECTS OF NICOTINE [J].
HUBBARD, JE ;
GOHD, RS .
PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 1975, 3 (03) :471-476
[9]
COHERENT SCATTERING AND THE ASSESSMENT OF MINERAL CONCENTRATION IN TRABECULAR BONE [J].
KERR, SA ;
KOURIS, K ;
WEBBER, CE ;
KENNETT, TJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (06) :1037-1047
[10]
STUDY OF THE RATIO OF ELASTIC TO INELASTIC-SCATTERING OF PHOTONS [J].
MANNINEN, S ;
PITKANEN, T ;
KOIKKALAINEN, S ;
PAAKKARI, T .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1984, 35 (02) :93-98