Automated on-line preconcentration system for electrothermal atomic absorption spectrometry for the determination of copper and molybdenum in sea-water

被引:45
作者
Sung, YH [1 ]
Liu, ZS [1 ]
Huang, SD [1 ]
机构
[1] NATL TSING HUA UNIV,DEPT CHEM,HSINCHU 30043,TAIWAN
关键词
atomic absorption spectrometry; preconcentration; copper; molybdenum; sea-water;
D O I
10.1039/a701657c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection accessory for electrothermal atomic absorption spectrometry was developed. The performance of the on-line preconcentration system was tested by determining Cu and Mo in sea-water. Calibration graphs constructed from the preconcentration of standards in 0.2% HNO3 solution were used. On-line preconcentration is computer-controlled. A miniature Muromac A-1 resin column was inserted at the tip of the AS-60 autosampler arm, A modification of the AS-60 autosampler in the tubing line and circuit allowed either flow of the sample through the column or operation of the autosampler in the normal mode. Retention of the metal ions as complexes on the microcolumn was achieved by using Muromac A-1 as the chelating resin; 20% v/v HNO3 was then used for elution, With a 198.6 mu l sample loop, the throughput is 14 samples h(-1). Detection limits are 0.009 mu g l(-1) for Cu (606.9 mu l sample loop) and 0.06 mu g l(-1) for Mo (50 mu l sample loop and repeated four times). The accuracy of the method was confirmed by the analysis of certified reference saline waters.
引用
收藏
页码:841 / 847
页数:7
相关论文
共 29 条
[1]   DETERMINATION OF TRACE-METALS IN SEAWATER BY GRAPHITE-FURNACE ATOMIC-ABSORPTION FOLLOWING ONLINE SEPARATION AND PRECONCENTRATION [J].
AZEREDO, LC ;
STURGEON, RE ;
CURTIUS, AJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (01) :91-98
[2]   DETERMINATION OF TRACE-METALS IN REFERENCE WATER STANDARDS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH ONLINE PRECONCENTRATION [J].
BEAUCHEMIN, D ;
BERMAN, SS .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1857-1862
[3]   DESIGN AND EVALUATION OF AN ONLINE MICROCOLUMN PRE-CONCENTRATION TECHNIQUE FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BEINROHR, E ;
CAKRT, M ;
RAPTA, M ;
TARAPCI, P .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (08) :1005-1007
[4]   FLOW-INJECTION ONLINE SORBENT EXTRACTION PRECONCENTRATION FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, Z ;
SPERLING, M ;
WELZ, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (07) :639-646
[5]   AN EFFICIENT FLOW-INJECTION SYSTEM WITH ONLINE ION-EXCHANGE PRECONCENTRATION FOR THE DETERMINATION OF TRACE AMOUNTS OF HEAVY-METALS BY ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, ZL ;
RUZICKA, J ;
HANSEN, EH .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :23-39
[6]   HIGH-EFFICIENCY LOW SAMPLE CONSUMPTION ONLINE ION-EXCHANGE PRE-CONCENTRATION SYSTEM FOR FLOW-INJECTION FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, ZL ;
WELZ, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (06) :543-546
[7]   Developments and trends in flow injection atomic absorption spectrometry [J].
Fang, ZL ;
Xu, SK ;
Tao, GH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (01) :1-24
[8]   DETERMINATION OF CHROMIUM(III), TITANIUM, VANADIUM, IRON(III), AND ALUMINUM BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY WITH AN ONLINE PRECONCENTRATING ION-EXCHANGE COLUMN [J].
HIRATA, S ;
UMEZAKI, Y ;
IKEDA, M .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :2602-2606
[9]   TRACE-METAL ENRICHMENT BY AUTOMATED ONLINE COLUMN PRECONCENTRATION FOR FLOW-INJECTION ATOMIC-ABSORPTION SPECTROMETRY [J].
HIRATA, S ;
HONDA, K ;
KUMAMARU, T .
ANALYTICA CHIMICA ACTA, 1989, 221 (01) :65-76