The functional consequences of chronic, physiologically effective intracortical microstimulation

被引:35
作者
Parker, Rebecca A. [1 ]
Davis, Tyler S. [2 ]
House, Paul A. [3 ]
Normann, Richard A. [2 ]
Greger, Bradley [2 ]
机构
[1] Univ Utah, Interdept Program Neurosci, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
[3] Univ Utah, Sch Med, Dept Neurosurg, Salt Lake City, UT USA
来源
BRAIN MACHINE INTERFACES: IMPLICATIONS FOR SCIENCE, CLINICAL PRACTICE AND SOCIETY | 2011年 / 194卷
关键词
micro-electrode array; motor cortex; feline; electromyogram; impedance; microstimulation; IRIDIUM OXIDE-FILMS; CORTICAL MICROSTIMULATION; ELECTRICAL MICROSTIMULATION; NEURAL STIMULATION; STRIATE CORTEX; BEHAVIORAL DETECTION; PRECENTRAL CORTEX; ELECTRODE ARRAY; MACAQUE MONKEYS; AUDITORY-CORTEX;
D O I
10.1016/B978-0-444-53815-4.00010-8
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Many studies have demonstrated the ability of chronically implanted multielectrode arrays (MEAs) to extract information from the motor cortex of both humans and nonhuman primates. Similarly, many studies have shown the ability of intracortical microstimulation to impart information to the brain via a single or a few electrodes acutely implanted in sensory cortex of nonhuman primates, but relatively few microstimulation studies characterizing chronically implanted MEAs have been performed. Additionally, device and tissue damage have been reported at the levels of microstimulation used in these studies. Whether the damage resulting from microstimulation impairs the ability of MEAs to chronically produce physiological effects, however, has not been directly tested. In this study, we examined the functional consequences of multiple months of periodic microstimulation via chronically implanted MEAs at levels capable of evoking physiological responses, that is, electromyogram (EMG) activity. The functionality of the MEA and neural tissue was determined by measuring impedances, the ability of microstimulation to evoke EMG responses, and the recording of action potentials. We found that impedances and the number of recorded action potentials followed the previously reported trend of decreasing over time in both animals that received microstimulation and those which did not receive microstimulation. Despite these trends, the ability to evoke EMG responses and record action potentials was retained throughout the study. The results of this study suggest that intracortical microstimulation via MEAs did not cause functional failure, suggesting that MEA-based microstimulation is ready to transition into subchronic (<30 days) human trials to determine whether complex spatiotemporal sensory percepts can be evoked by patterned microstimulation.
引用
收藏
页码:145 / 165
页数:21
相关论文
共 59 条
[1]  
[Anonymous], EMBC 2009 ANN INT C
[2]   VISUAL SENSATIONS PRODUCED BY INTRACORTICAL MICROSTIMULATION OF THE HUMAN OCCIPITAL CORTEX [J].
BAK, M ;
GIRVIN, JP ;
HAMBRECHT, FT ;
KUFTA, CV ;
LOEB, GE ;
SCHMIDT, EM .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (03) :257-259
[3]   Visuotopic mapping through a multichannel stimulating implant in primate V1 [J].
Bradley, DC ;
Troyk, PR ;
Berg, JA ;
Bak, M ;
Cogan, S ;
Erickson, R ;
Kufta, C ;
Mascaro, M ;
McCreery, D ;
Schmidt, EM ;
Towle, VL ;
Xu, H .
JOURNAL OF NEUROPHYSIOLOGY, 2005, 93 (03) :1659-1670
[4]   Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation [J].
Cogan, SF ;
Guzelian, AA ;
Agnew, WF ;
Yuen, TGH ;
McCreery, DB .
JOURNAL OF NEUROSCIENCE METHODS, 2004, 137 (02) :141-150
[5]   Neural stimulation and recording electrodes [J].
Cogan, Stuart F. .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2008, 10 :275-309
[6]   Sputtered Iridium Oxide Films for Neural Stimulation Electrodes [J].
Cogan, Stuart F. ;
Ehrlich, Julia ;
Plante, Timothy D. ;
Smirnov, Anton ;
Shire, Douglas B. ;
Gingerich, Marcus ;
Rizzo, Joseph F. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 89B (02) :353-361
[7]   Complex movements evoked by microstimulation of the ventral intraparietal area [J].
Cooke, DF ;
Taylor, CSR ;
Moore, T ;
Graziano, MSA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (10) :6163-6168
[8]   Deep brain stimulation:: Postoperative issues [J].
Deuschl, Guenther ;
Herzog, Jan ;
Kleiner-Fisman, Galit ;
Kubu, Cynthia ;
Lozano, Andres M. ;
Lyons, Kelly E. ;
Rodriguez-Oroz, Maria C. ;
Tamma, Filippo ;
Troester, Alexander I. ;
Vitek, Jerrold L. ;
Volkmann, Jens ;
Voon, Valerie .
MOVEMENT DISORDERS, 2006, 21 :S219-S237
[9]   Laminar variation in threshold for detection of electrical excitation of striate cortex by macaques [J].
DeYoe, EA ;
Lewine, JD ;
Doty, RW .
JOURNAL OF NEUROPHYSIOLOGY, 2005, 94 (05) :3443-3450
[10]   Single-Unit Stability Using Chronically Implanted Multielectrode Arrays [J].
Dickey, Adam S. ;
Suminski, Aaron ;
Amit, Yali ;
Hatsopoulos, Nicholas G. .
JOURNAL OF NEUROPHYSIOLOGY, 2009, 102 (02) :1331-1339