Assessing the accuracy of high-resolution X-ray computed tomography of primate trabecular bone by comparisons with histological sections

被引:115
作者
Fajardo, RJ [1 ]
Ryan, TM
Kappelman, J
机构
[1] SUNY Stony Brook, Dept Anat Sci, Interdepartmental Doctoral Program Anthropol Sci, Stony Brook, NY 11794 USA
[2] Univ Texas, Dept Anthropol, Austin, TX 78712 USA
关键词
high-resolution X-ray computed tomography; primate trabecular bone; stereology; thresholding;
D O I
10.1002/ajpa.10086
中图分类号
Q98 [人类学];
学科分类号
030303 ;
摘要
Different lines of evidence suggest that trabecular bone architecture contains a functional signal related to an organism's locomotor behavior. An understanding of the interspecific and intraspecific variation in extant nonhuman primate trabecular structure is needed to evaluate its usefulness as a tool to reconstruct the locomotor habits of extinct primates. High-resolution Xray computed tomography (HRXCT) is a new imaging approach with a resolution in the tens of microns that allows nondestructive access to the internal structure of bony elements. Previous studies indicate that such resolution is necessary to accurately quantify structural parameters of trabecular bone. The primary goal of this study was to test the accuracy of HRXCT by comparing stereological measurements from HRXCT images and histological thin sections of cancellous bone taken from the proximal femur and humerus of baboons. To this end, 11 bone samples were scanned on an HRXCT scanner and then thin-sectioned to reveal the scanned plane. HRXCT images were thresholded using a modified half-maximum height protocol. The stereological measurements included bone volume fraction (BV/TV), trabecular number (Tb.N), bone surface to volume ratio (BS/BV), trabecular thickness (Tb.Th), and trabecular spacing (Tb.Sp). The measurement errors on the HRXCT images were 10.90% for BV/TV, 6.06% for Tb.N, 14.19% for BS/BV, 14.33% for Tb.Th, and 7.09% for Tb.Sp, but none of these measurements were significantly different from the histological standards (a = 0.05). A second goal of this study was to examine the influence of thresholding, a necessary step in any morphometric study using computed tomography, on the accuracy of the quantitative morphometry. Threshold values derived from a modified half-maximum height protocol showed that parameters derived from the region of interest (area in which stereological measurements were later taken) produced better reconstructions of the actual bone structure than threshold values derived from more inclusive areas of bone. We conclude that HRXCT can accurately reconstruct the complex architecture of trabecular bone, and that thresholding is a nontrivial step in trabecular bone studies, with even slight changes in the protocol greatly affecting the morphometric data. HRXCT represents a valuable analytical tool that should be of interest to a great many researchers in physical anthropology because it allows nondestructive access to internal morphology, thereby preserving valuable and limited skeletal collections. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 57 条
[1]  
[Anonymous], BAUPRINZIPIEN SAUGER
[2]   Adaptive changes in trabecular architecture in relation to functional strain patterns and disuse [J].
Biewener, AA ;
Fazzalari, NL ;
Konieczynski, DD ;
Baudinette, RV .
BONE, 1996, 19 (01) :1-8
[3]   3D COMPUTED X-RAY TOMOGRAPHY OF HUMAN CANCELLOUS BONE AT 8 MU-M SPATIAL AND 10(-4) ENERGY RESOLUTION [J].
BONSE, U ;
BUSCH, F ;
GUNNEWIG, O ;
BECKMANN, F ;
PAHL, R ;
DELLING, G ;
HAHN, M ;
GRAEFF, W .
BONE AND MINERAL, 1994, 25 (01) :25-38
[4]  
BROCHU CA, 1999, J VERT PALEONT S, V19, P34
[5]   Noninvasive markers of bone metabolism in the rhesus monkey: Normal effects of age and gender [J].
Cahoon, S ;
Boden, SD ;
Gould, KG ;
Vailas, AC .
JOURNAL OF MEDICAL PRIMATOLOGY, 1996, 25 (05) :333-338
[6]  
Cerroni AM, 2000, AM J PHYS ANTHROPOL, V113, P389, DOI 10.1002/1096-8644(200011)113:3<389::AID-AJPA9>3.0.CO
[7]  
2-I
[8]   The effect of advancing age on bone mineral content of female rhesus monkeys [J].
Champ, JE ;
Binkley, N ;
Havighurst, T ;
Colman, RJ ;
Kemnitz, JW ;
Roecker, EB .
BONE, 1996, 19 (05) :485-492
[9]   CALCULATION OF CROSS-SECTIONAL GEOMETRY OF BONE FROM CT IMAGES WITH APPLICATION IN POSTMENOPAUSAL WOMEN [J].
CORCORAN, TA ;
SANDLER, RB ;
MYERS, ER ;
LEBOWITZ, HH ;
HAYES, WC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (04) :626-633