Development of an ultrasonic tomography system for application in pneumatic conveying

被引:19
作者
Brown, GJ [1 ]
Reilly, D [1 ]
Mills, D [1 ]
机构
[1] GLASGOW CALEDONIAN UNIV, DEPT PHYS SCI, GLASGOW G4 0BA, LANARK, SCOTLAND
关键词
D O I
10.1088/0957-0233/7/3/022
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper details the development of a tomographic technique for imaging gas-solid flow distributions in pneumatic conveying pipelines. The technique utilizes ultrasonic transmission-mode measurements constrained to the megahertz region. Image reconstruction is performed by an efficient backprojection method implemented with standard graphics algorithms. Simulated reconstructions of dense and dilute distributions are presented. These results demonstrate the capabilities and limitations of the technique. Aspects of transducer array design are also addressed. An optimal arrangement for imaging dense phase flow distributions is derived and the characteristics of air-loaded and water-loaded, matched and unmatched peizoceramic transducers are evaluated. The validity of the technique is demonstrated using a low-frequency (72 kHz) system constructed with prototype fan-shaped-beam electrostatic transducers. Further development of the technique for practical application is discussed.
引用
收藏
页码:396 / 405
页数:10
相关论文
共 36 条
[1]  
[Anonymous], 1987, ACOUSTIC WAVES DEVIC
[2]  
[Anonymous], PNEUMATIC CONVEYING
[3]   ULTRASONIC SENSORS IN THE CHEMICAL AND PROCESS INDUSTRIES [J].
ASHER, RC .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (10) :959-963
[4]  
BLACKLEDGE JM, 1993, IEE C ULTRASOUND PRO
[5]   ALGORITHM FOR COMPUTER CONTROL OF A DIGITAL PLOTTER [J].
BRESENHAM, JE .
IBM SYSTEMS JOURNAL, 1965, 4 (01) :25-30
[6]  
BRODOWICZ K, 1993, TOMOGRAPHIC TECHNIQUES FOR PROCESS DESIGN AND OPERATION, P361
[7]  
Brown G.J., 1995, P PROC TOM, P176
[8]  
BROWN GJ, 1995, IN PRESS P ULTR INT
[9]  
Chang J. S., 1984, MEASURING TECHNIQUES, P319
[10]  
CROWTHER JM, 1995, P 2 ECAPT C BERG, P166