Three-dimensional gadolinium-enhanced magnetic resonance venography in suspected thrombo-occlusive disease of the central chest veins

被引:40
作者
Kroencke, TJ [1 ]
Taupitz, M [1 ]
Arnold, R [1 ]
Fritsche, L [1 ]
Hamm, B [1 ]
机构
[1] Humboldt Univ, Univ Klinikum Charite, Med Klin, Inst Radiol, D-10098 Berlin, Germany
关键词
diagnostic techniques; cardiovascular; magnetic resonance angiography; thorax; veins; venous thrombosis;
D O I
10.1378/chest.120.5.1570
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
Study objective: To determine the usefulness of high-resolution three-dimensional (3D) gadolinium-enhanced magnetic resonance venography (MRV) in the evaluation of central venous thrombo-occlusive disease of the chest. Design: Prospective study. Setting: University hospital. Patients: Sixteen consecutive patients with clinically suspected thrombosis of the superior vena cava, subclavian, brachiocephalic/innominate, internal jugular, or axillary veins. Thirteen patients had a neoplasm, two patients had a connective tissue disease, and one patient had a history of strenuous exercise. Twelve of 16 patients had prior central venous catheter placement. MRI was correlated with color-coded duplex sonography (CCDS) in 7 of 16 patients, digital subtraction angiography (DSA) in 3 of 16 patients, and CT in 2 of 16 patients. Intervention: Contrast-enhanced MRV was performed in a total of 20 examinations. A 3D data set (gradient echo; time to repeat, 4.6 ms; time to echo, 1.8 ms; flip angle, 30 degrees; time of acquisition, 23 s; 512 matrix/64 partitions; slice thickness, 1.5 mm) was acquired in the arterial and venous phase. Overall image quality was assessed on a 5-point scale. The presence, site, and extent of thrombus, as well as presence of an intravascular device, were determined. Measurements and results: Overall image quality was rated very good (1 point) in 7 of 16 cases (44%) and good (2 points) in 9 of 16 cases (56%). Thrombus was detected in 16 of 16 patients, and complete extent of disease could be determined in 15 of 16 patients (94%). MRV did not miss any finding obtained by CCDS, DSA, or CT, and provided additional information in 6 of 16 examinations (38%). Conclusion: Contrast-enhanced MRV is a fast and reliable noninvasive procedure with excellent results regarding detection and determination of the extent of thrombo-occlusive disease of the chest veins.
引用
收藏
页码:1570 / 1576
页数:7
相关论文
共 48 条
[1]
AbuRahma A F, 1996, Cardiovasc Surg, V4, P783, DOI 10.1016/S0967-2109(96)00025-7
[2]
DIGITAL SUBTRACTION VENOGRAPHY IN CENTRAL VENOUS OBSTRUCTION [J].
BENENATI, JF ;
BECKER, GJ ;
MAIL, JT ;
HOLDEN, RW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (04) :685-688
[3]
CONTRAST VENOGRAPHY OF THE LEG - DIAGNOSTIC EFFICACY, TOLERANCE, AND COMPLICATION RATES WITH IONIC AND NONIONIC CONTRAST-MEDIA [J].
BETTMANN, MA ;
ROBBINS, A ;
BRAUN, SD ;
WETZNER, S ;
DUNNICK, NR ;
FINKELSTEIN, J .
RADIOLOGY, 1987, 165 (01) :113-116
[4]
UPPER EXTREMITY DEEP VENOUS THROMBOSIS - UNDERDIAGNOSED AND POTENTIALLY LETHAL [J].
BLACK, MD ;
FRENCH, GJ ;
RASULI, P ;
BOUCHARD, AC .
CHEST, 1993, 103 (06) :1887-1890
[5]
BROGLIA L, 2000, 12 EUR C RAD SCI PRO, P300
[6]
CONTEMPORARY VENOUS IMAGING [J].
CRONAN, JJ .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1991, 14 (02) :87-97
[7]
Central venous thrombosis: An early and frequent complication in cancer patients bearing long-term silastic catheter. A prospective study [J].
DeCicco, M ;
Matovic, M ;
Balestreri, L ;
Panarello, G ;
Fantin, D ;
Morassut, S ;
Testa, V .
THROMBOSIS RESEARCH, 1997, 86 (02) :101-113
[8]
UPPER EXTREMITY THROMBOSIS - ETIOLOGY AND PROGNOSIS [J].
DEMETER, SL ;
PRITCHARD, JS ;
PIEDAD, OH ;
CORDASCO, EM ;
TAHERJ, S .
ANGIOLOGY, 1982, 33 (11) :743-755
[9]
UPPER EXTREMITY RADIONUCLIDE VENOGRAPHY IN THE DIAGNOSIS AND MANAGEMENT OF VENOUS DISEASE ASSOCIATED WITH INTRAVENOUS CATHETERS [J].
DHEKNE, RD ;
MOORE, WH ;
PETERS, C ;
DUDRICK, SJ ;
LONG, SE .
ANGIOLOGY, 1988, 39 (10) :907-914
[10]
THROMBOSIS AND EMBOLISM IN LONG-TERM CENTRAL VENOUS ACCESS FOR PARENTERAL-NUTRITION [J].
DOLLERY, CM ;
SULLIVAN, ID ;
BAURAIND, O ;
BULL, C ;
MILLA, PJ .
LANCET, 1994, 344 (8929) :1043-1045