Analysis of gaseous toxic industrial compounds and chemical warfare agent simulants by atmospheric pressure ionization mass spectrometry

被引:35
作者
Cotte-Rodríguez, I [1 ]
Justes, DR [1 ]
Nanita, SC [1 ]
Noll, RJ [1 ]
Mulligan, CC [1 ]
Sanders, NL [1 ]
Cooks, RG [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
D O I
10.1039/b513605a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The suitability of atmospheric pressure chemical ionization mass spectrometry as sensing instrumentation for the real-time monitoring of low levels of toxic compounds is assessed, especially with respect to public safety applications. Gaseous samples of nine toxic industrial compounds, NH3, H2S, Cl-2, CS2, SO2, C2H4O, HBr, C6H6 and AsH3, and two chemical warfare agent simulants, dimethyl methylphosphonate (DMMP) and methyl salicylate (MeS), were studied. API-MS proves highly suited to this application, with speedy analysis times (<30 seconds), high sensitivity, high selectivity towards analytes, good precision, dynamic range and accuracy. Tandem MS methods were implemented in selected cases for improved selectivity, sensitivity, and limits of detection. Limits of detection in the parts-per-billion and parts-pertrillion range were achieved for this set of analytes. In all cases detection limits were well below the compounds' permissible exposure limits (PELs), even in the presence of added complex mixtures of alkanes. Linear responses, up to several orders of magnitude, were obtained over the concentration ranges studied (sub-ppb to ppm), with relative standard deviations less than 3%, regardless of the presence of alkane interferents. Receiver operating characteristic (ROC) curves are presented to show the performance trade-off between sensitivity, probability of correct detection, and false positive rate. A dynamic sample preparation system for the production of gas phase analyte concentrations ranging from 100 pptr to 100 ppm and capable of admixing gaseous matrix compounds and control of relative humidity and temperature is also described.
引用
收藏
页码:579 / 589
页数:11
相关论文
共 87 条
[1]  
[Anonymous], 2005, Wikipedia
[2]  
[Anonymous], 2005, NIOSH PUBL
[3]  
Badman ER, 2000, J MASS SPECTROM, V35, P659, DOI 10.1002/1096-9888(200006)35:6<659::AID-JMS5>3.0.CO
[4]  
2-V
[5]   DETERMINATION OF PART-PER-TRILLION BY VOLUME LEVELS OF ATMOSPHERIC CARBON-DISULFIDE BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BANDY, AR ;
TUCKER, BJ ;
MAROULIS, PJ .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :1310-1314
[7]   Occupational exposure to aromatic hydrocarbons at a coke plant: Part II. Exposure assessment of volatile organic compounds [J].
Bieniek, G ;
Kurkiewicz, S ;
Wilczok, T ;
Klimek, K ;
Swiatkowska, L ;
Lusiak, A .
JOURNAL OF OCCUPATIONAL HEALTH, 2004, 46 (03) :181-186
[8]   Occupational exposure to aromatic hydrocarbons at a coke plant: Part I. Identification of hydrocarbons in air and their metabolites in urine by a gas chromatography-mass spectrometry method [J].
Bieniek, G ;
Kurkiewicz, S ;
Wilczok, T .
JOURNAL OF OCCUPATIONAL HEALTH, 2004, 46 (03) :175-180
[9]   International symposium: Recent advances in benzene toxicity [J].
Bird, MG ;
Greim, H ;
Snyder, R ;
Rice, JM .
CHEMICO-BIOLOGICAL INTERACTIONS, 2005, 153 :1-5
[10]   Towards the hand-held mass spectrometer: design considerations, simulation, and fabrication of micrometer-scaled cylindrical ion traps [J].
Blain, MG ;
Riter, LS ;
Cruz, D ;
Austin, DE ;
Wu, GX ;
Plass, WR ;
Cooks, RG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 236 (1-3) :91-104