Simultaneous emission and transmission (SET) scanning in neurological PET studies

被引:11
作者
Meikle, SR
Eberl, S
Hooper, PK
Fulham, MJ
机构
[1] PET Department, Medical Imaging Services, Royal Prince Alfred Hospital, Camperdown, NSW 2050, Missenden Road
关键词
emission computed tomography; metabolism; glucose; attenuation values; techniques;
D O I
10.1097/00004728-199705000-00028
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We evaluated the impact of simultaneous emission and transmission (SET) measurements on quantification and noise in neurological PET studies. Method: Bias in SET was measured as a function of emission count rate and used to predict distortion in simulated FDG tissue curves and its effect on model parameter estimates. Studies were performed on a brain phantom and a patient to verify predicted bias and examine the effect of SET on noise. Results: In static imaging, SET underestimated trace; concentration by similar to 2%. In kinetic studies, tracer concentration was overestimated initially and underestimated during the mid to late part of the study, but bias in measurement of glucose metabolic rate was <5% by simulation and <10% in the patient study. SET imaging takes 10% longer than the emission part of a conventional scan to achieve comparable statistics. Conclusion: Accurate neurological PET studies can be performed with SET. The relatively small bias can be predicted and potentially corrected.
引用
收藏
页码:487 / 497
页数:11
相关论文
共 23 条
[1]   A CONVOLUTION-SUBTRACTION SCATTER CORRECTION METHOD FOR 3D PET [J].
BAILEY, DL ;
MEIKLE, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :411-424
[2]  
BAILEY DL, 1987, J NUCL MED, V28, P844
[3]  
CARSON RE, 1988, J NUCL MED, V29, P1558
[4]  
CASEY ME, 1992, THESIS U TENNESSEE
[5]   SCATTER DISTRIBUTION IN TRANSMISSION MEASUREMENTS WITH POSITRON EMISSION TOMOGRAPHY [J].
CHAN, B ;
BERGSTROM, M ;
PALMER, MR ;
SAYRE, C ;
PATE, BD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (02) :296-301
[6]   UNIFIED DEADTIME CORRECTION MODEL FOR PET [J].
DAUBEWITHERSPOON, ME ;
CARSON, RE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :267-275
[7]   POST-INJECTION TRANSMISSION ATTENUATION MEASUREMENTS FOR PET [J].
DAUBEWITHERSPOON, ME ;
CARSON, RE ;
GREEN, MV .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :757-761
[8]   MODELS FOR COMPUTER-SIMULATION STUDIES OF INPUT FUNCTIONS FOR TRACER KINETIC MODELING WITH POSITRON EMISSION TOMOGRAPHY [J].
FENG, D ;
HUANG, SC ;
WANG, XM .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1993, 32 (02) :95-110
[9]  
Graham Michael M., 1993, Journal of Nuclear Medicine, V34, p257P
[10]   3-D PHANTOM TO SIMULATE CEREBRAL BLOOD-FLOW AND METABOLIC IMAGES FOR PET [J].
HOFFMAN, EJ ;
CUTLER, PD ;
DIGBY, WM ;
MAZZIOTTA, JC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :616-620