Personal computer-based 3-dimensional ultrasound biomicroscopy of the anterior segment

被引:12
作者
Iezzi, R [1 ]
Rosen, RB [1 ]
Tello, C [1 ]
Liebmann, J [1 ]
Walsh, JB [1 ]
Ritch, R [1 ]
机构
[1] NEW YORK EYE & EAR INFIRM, DEPT OPHTHALMOL, GLAUCOMA SERV, NEW YORK, NY 10003 USA
关键词
D O I
10.1001/archopht.1996.01100130512001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To develop a practical, inexpensive system for 3-dimensional ultrasound biomicroscopic imaging of the anterior segment with a commercially available high-frequency ultrasound imager and a personal computer. Methods: Sequential, high-frequency, ultrasound biomicroscopic images of the anterior segment were obtained with a motorized scanning control arm designed in our imaging laboratory. Images were acquired by a personal computer-based video capture device. Ultrasound slice data were then reconstructed as 3-dimensional volumetric images by a personal computer and commercially available software. Results: Four 3-dimensional visualization formats were developed to enhance the clinical utility of high-frequency ultrasound. Rotational animation sequences were created that detailed the extent and anatomy of a filtering bleb, intraocular lens subluxation, focal angle closure from an iridociliary cyst, intraocular foreign bodies, and an iris tumor. Conclusions: Three-dimensional, high-frequency ultrasound of the anterior segment enhances our ability to visualize spatial relationships between adjacent anatomic structures, The low cost and ease of use of this system make widespread clinical application practical.
引用
收藏
页码:520 / 524
页数:5
相关论文
共 21 条
[1]   3-DIMENSIONAL RECONSTRUCTION OF ULTRASOUND IMAGES OF THE UTERINE CAVITY [J].
BALEN, FG ;
ALLEN, CM ;
GARDENER, JE ;
SIDDLE, NC ;
LEES, WR .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (787) :588-591
[2]  
COLEMAN DJ, 1992, RADIOL CLIN N AM, V30, P1105
[3]  
Desai R, 1993, Biomed Sci Instrum, V29, P377
[4]   3-DIMENSIONAL US - PRELIMINARY CLINICAL-EXPERIENCE [J].
HAMPER, UM ;
TRAPANOTTO, V ;
SHETH, S ;
DEJONG, MR ;
CASKEY, CI .
RADIOLOGY, 1994, 191 (02) :397-401
[5]   3D-SURFACE RECONSTRUCTION OF INTRAVASCULAR ULTRASOUND IMAGES USING PERSONAL-COMPUTER HARDWARE AND A MOTORIZED CATHETER CONTROL [J].
KLEIN, HM ;
GUNTHER, RW ;
VERLANDE, M ;
SCHNEIDER, W ;
VORWERK, D ;
KELCH, J ;
HAMM, M .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1992, 15 (02) :97-101
[6]  
LIEBMANN JM, 1995, OPHTHALMOLOGY, V102, P446
[7]  
NOUBYMAHMOUD G, 1993, OPHTHALMIC SURG LAS, V24, P94
[8]  
PAVLIN CJ, 1990, OPHTHALMOLOGY, V97, P244
[9]   ULTRASOUND BIOMICROSCOPY IN THE ASSESSMENT OF ANTERIOR SCLERAL DISEASE [J].
PAVLIN, CJ ;
EASTERBROOK, M ;
HURWITZ, JJ ;
HARASIEWICZ, K ;
FOSTER, FS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1993, 116 (05) :628-635
[10]   DETERMINATION OF HAPTIC POSITION OF TRANSSCLERALLY FIXATED POSTERIOR CHAMBER INTRAOCULAR LENSES BY ULTRASOUND BIOMICROSCOPY [J].
PAVLIN, CJ ;
ROOTMAN, D ;
ARSHINOFF, S ;
HARASIEWICZ, K ;
FOSTER, FS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (05) :573-577