D-dimer testing for suspected pulmonary embolism in outpatients

被引:212
作者
Perrier, A
Desmarais, S
Goehring, C
deMoerloose, P
Morabia, A
Unger, PF
Slosman, D
Junod, A
Bounameaux, H
机构
[1] UNIV HOSP GENEVA, MED CLIN, DIV CLIN EPIDEMIOL, CH-1211 GENEVA 14, SWITZERLAND
[2] UNIV HOSP GENEVA, MED CLIN, DIV MED & SURG EMERGENCIES, CH-1211 GENEVA 14, SWITZERLAND
[3] UNIV HOSP GENEVA, MED CLIN, DIV NUCL MED, CH-1211 GENEVA 14, SWITZERLAND
关键词
D O I
10.1164/ajrccm.156.2.9702032
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The plasma level of D-dimer, a fibrin degradation product (FDP), is nearly always increased in the presence of acute pulmonary embolism (PE). Hence, a normal D-dimer level (below a cutoff value of 500 mu g/L by enzyme-linked immunosorbent assay [ELISA]) may allow the exclusion of PE. To assess the negative predictive value of a D-dimer concentration below 500 mu g/L in outpatients with suspected PE, and the safety of withholding anticoagulant treatment from such patients, we performed D-dimer assays, lower limb venous compression ultrasonography, and lung scans in 671 consecutive outpatients presenting in the Emergency Center of the Geneva University Hospital with suspected PE. Pulmonary angiography was reserved for patients with an inconclusive noninvasive workup. Patients with a normal D-dimer concentration were discharged without anticoagulant treatment and followed for 3 mo. The prevalence of PE was 29%, and D-dimer (using a cutoff of 500 mu g/L) had a diagnostic sensitivity for PE of 99.5%. Overall diagnostic specificity of D-dimer was 41%, but it was lower among older patients. Of the 198 patients with a D-dimer concentration below the cutoff value, 196 were free of PE, one had a PE, and one had incomplete information because of loss to follow-up. Thus, the negative predictive value of D-dimer concentration fell between 197 of 198 and 196 of 198 cases of PE (99% [95% CI: 96.4 to 99.9]). Using a cutoff value of 4,000 mu g/L, the overall specificity of D-dimer concentration for PE was 93.1%. In conclusion, a plasma D-dimer concentration below 500 mu g/L allows the exclusion of PE in 29% of outpatients suspected of having PE. Withholding anticoagulation from such patients is associated with a conservative 1% risk of thromboembolic events during follow-up.
引用
收藏
页码:492 / 496
页数:5
相关论文
共 31 条
  • [1] PULMONARY-EMBOLISM - DIAGNOSIS WITH MULTIPLE IMAGING MODALITIES
    ALDERSON, PO
    MARTIN, EC
    [J]. RADIOLOGY, 1987, 164 (02) : 297 - 312
  • [2] BARRITT DW, 1960, LANCET, V1, P1309
  • [3] REAL-TIME ULTRASONOGRAPHY FOR THE DIAGNOSIS OF LOWER-EXTREMITY DEEP VENOUS THROMBOSIS - THE WAVE OF THE FUTURE
    BECKER, DM
    PHILBRICK, JT
    ABBITT, PL
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1989, 149 (08) : 1731 - 1734
  • [4] D-Dimer testing and acute venous thromboembolism - A shortcut to accurate diagnosis?
    Becker, DM
    Philbrick, JT
    Bachhuber, TL
    Humphries, JE
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1996, 156 (09) : 939 - 946
  • [5] IS BILATERAL LOWER-EXTREMITY COMPRESSION SONOGRAPHY USEFUL AND COST-EFFECTIVE IN THE EVALUATION OF SUSPECTED PULMONARY-EMBOLISM
    BEECHAM, RP
    DORFMAN, GS
    CRONAN, JJ
    SPEARMAN, MP
    MURPHY, TP
    SCOLA, FH
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (06) : 1289 - 1292
  • [6] MEASUREMENT OF D-DIMER IN PLASMA AS DIAGNOSTIC-AID IN SUSPECTED PULMONARY-EMBOLISM
    BOUNAMEAUX, H
    CIRAFICI, P
    DEMOERLOOSE, P
    SCHNEIDER, PA
    SLOSMAN, D
    REBER, G
    UNGER, PF
    [J]. LANCET, 1991, 337 (8735) : 196 - 200
  • [7] Bounameaux H, 1990, Blood Coagul Fibrinolysis, V1, P577, DOI 10.1097/00001721-199010000-00045
  • [8] BOUNAMEAUX H, 1994, THROMB HAEMOSTASIS, V71, P1
  • [9] BOUNAMEAUX H, 1988, LANCET, V2, P628
  • [10] CADROY Y, 1992, NOUV REV FR HEMATOL, V34, P43