The Impact of Platinum Loading on Oxygen Transport Resistance

被引:370
作者
Greszler, Thomas A. [1 ]
Caulk, David [1 ]
Sinha, Puneet [1 ]
机构
[1] Gen Motors Res & Dev, Electrochem Energy Res Lab, Honeoye Falls, NY 14450 USA
关键词
FUEL-CELL CATHODE; AGGLOMERATE MODEL; CATALYST LAYERS; REDUCTION; MEMBRANE; FILM; ELECTRODES; PEMFCS;
D O I
10.1149/2.061212jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The effect of cathode platinum loading on oxygen transport resistance in a fuel cell electrode was determined by measuring limiting current in fuel cells over a wide range of platinum loadings (0.03 to 0.40 mg(Pt)/cm(2)). The measurements show that the electrode oxygen transport resistance is inversely proportional to platinum loading or, equivalently, platinum surface area, and is mathematically similar to a 12 s/cm resistive film coating the active platinum sites. At low platinum loading this anomalous resistance significantly reduces the partial pressure of oxygen at the platinum surface and seriously degrades fuel cell performance at high power conditions. The magnitude of this film-like resistance is equivalent to similar to 35 nm of bulk-like ionomer but only 4-10 nm, assuming uniform coating, is present in the electrode. Alternatively, 380 nm diameter agglomerates with 20 nm of ionomer coating their external surface would create the same resistance, but such agglomerates are not apparent in SEM micrographs. As a result, the source of this resistance remains unknown, and further investigations are required to understand and mitigate it. (C) 2012 The Electrochemical Society. [DOI: 10.1149/2.061212jes] All rights reserved.
引用
收藏
页码:F831 / F840
页数:10
相关论文
共 28 条
[1]   Measurement of Oxygen Transport Resistance in PEM Fuel Cells by Limiting Current Methods [J].
Baker, Daniel R. ;
Caulk, David A. ;
Neyerlin, Kenneth C. ;
Murphy, Michael W. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2009, 156 (09) :B991-B1003
[2]  
Bonakdarpour A., 2007, ECS M, V702, P505
[3]   Oxygen and hydrogen permeation properties and water uptake of Nafion(R) 117 membrane and recast film for PEM fuel cell [J].
Broka, K ;
Ekdunge, P .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1997, 27 (02) :117-123
[4]  
Carter R. N., 2007, ECS T, V11, P7
[5]   Effects of an agglomerate size distribution on the PEFC agglomerate model [J].
Epting, William K. ;
Litster, Shawn .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (10) :8505-8511
[6]   Activity benchmarks and requirements for Pt, Pt-alloy, and non-Pt oxygen reduction catalysts for PEMFCs [J].
Gasteiger, HA ;
Kocha, SS ;
Sompalli, B ;
Wagner, FT .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2005, 56 (1-2) :9-35
[7]   An evaluation of the macro-homogeneous and agglomerate model for oxygen reduction in PEMFCs [J].
Gloaguen, F ;
Convert, P ;
Gamburzev, S ;
Velev, OA ;
Srinivasan, S .
ELECTROCHIMICA ACTA, 1998, 43 (24) :3767-3772
[8]  
Gu W., 2003, HDB FUEL CELLS FUNDA
[9]   Effect of agglomeration of Pt/C catalyst on hydrogen peroxide formation [J].
Inaba, M ;
Yamada, H ;
Tokunaga, J ;
Tasaka, A .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 2004, 7 (12) :A474-A476
[10]   Non-equilibrium surface reactions - a factor in determining steady state diffusion flux [J].
Islam, MA ;
Buschatz, H ;
Paul, D .
JOURNAL OF MEMBRANE SCIENCE, 2002, 204 (1-2) :379-384