Effect of elution modes on protein separation was investigated using cross-axis coil planet centrifuge (cross-axis CPC) with two different types of coiled columns, i.e., eccentric coil and toroidal coil assemblies. Myoglobin and lysozyme were separated with an aqueous two-phase solvent system composed of 12.5% (w/w) polyethylene glycol 1000 and 12.5% (w/w) dibasic potassium phosphate. The substantial effect of elution modes was observed by the toroidal coil, while the negative result was given at the eccentric coil. Using the toroidal coil, higher peak resolution of proteins was attained at the tail to head elution mode. In the outward lower phase mobile elution mode, the satisfactory separation was obtained by both eccentric coil and toroidal coil assemblies. However, in the inward upper phase mobile elution mode, the toroidal coil produced a broad and asymmetric myoglobin peak. The analysis using polyacrylamide gel electrophoresis revealed that the toroidal coil partially separated the components originally present in the myoglobin sample. As the result, a modified equation was devised to express the peak resolution (Rs) using the lysozyme peak. The overall results indicated that the toroidal coil produced better partition efficiency than the eccentric coil under the optimized experimental condition including the direction of the Coriolis force acting on the mobile phase in the toroidal coil.
引用
收藏
页码:139 / 150
页数:12
相关论文
共 16 条
[1]
Conway WD., 1990, COUNTERCURRENT CHROM
[2]
GOUPY J, 1995, MODEN COUNTERCURRENT, P47
[3]
CROSS-AXIS SYNCHRONOUS FLOW-THROUGH COIL PLANET CENTRIFUGE FREE OF ROTARY SEALS FOR PREPARATIVE COUNTERCURRENT CHROMATOGRAPHY .1. APPARATUS AND ANALYSIS OF ACCELERATION [J].
ITO, Y .
SEPARATION SCIENCE AND TECHNOLOGY, 1987, 22 (8-10) :1971-1987
[4]
CROSS-AXIS SYNCHRONOUS FLOW-THROUGH COIL PLANET CENTRIFUGE FREE OF ROTARY SEALS FOR PREPARATIVE COUNTERCURRENT CHROMATOGRAPHY .2. STUDIES ON PHASE DISTRIBUTION AND PARTITION EFFICIENCY IN COAXIAL COILS [J].
ITO, Y .
SEPARATION SCIENCE AND TECHNOLOGY, 1987, 22 (8-10) :1989-2009
[5]
Effects of coriolis force on countercurrent chromatography [J].
Ito, Y ;
Ma, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (1-2) :1-17
[6]
Toroidal coil counter-current chromatography study of the mass transfer rate of proteins in aqueous-aqueous polymer phase system [J].
Ito, Y ;
Matsuda, K ;
Ma, Y ;
Qi, L .
JOURNAL OF CHROMATOGRAPHY A, 1998, 802 (02) :277-283
[7]
Ito Y., 1996, High-Speed Countercurrent Chromatography
[8]
MANDAVA NB, 1988, COUNTECURRENT CHROMA
[9]
Toroidal coil counter-current chromatography - Achievement of high resolution by optimizing flow-rate, rotation speed, sample volume and tube length [J].
Matsuda, K ;
Matsuda, S ;
Ito, Y .
JOURNAL OF CHROMATOGRAPHY A, 1998, 808 (1-2) :95-104
[10]
STUDIES ON A NEW CROSS-AXIS COIL PLANET CENTRIFUGE FOR PERFORMING COUNTERCURRENT CHROMATOGRAPHY .2. PATH AND ACCELERATION OF COILS AND COMPARISON WITH TYPE-J COIL PLANET CENTRIFUGE [J].
MENET, JM ;
ITO, Y .
JOURNAL OF CHROMATOGRAPHY, 1993, 644 (02) :231-238