The spectrophotometric determination of trace molybdenum (VI) after collection and elution as molybdate ion on protonated chitin

被引:45
作者
Hoshi, S [1 ]
Konuma, K [1 ]
Sugawara, K [1 ]
Uto, M [1 ]
Akatsuka, K [1 ]
机构
[1] KITAMI INST TECHNOL,DEPT FUNCT MAT,KITAMI,HOKKAIDO 090,JAPAN
关键词
trace molybdenum; chitin; molybdate ion;
D O I
10.1016/S0039-9140(97)00051-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Collection and elution method for inorganic anion on protonated chitin has been applied to the spectrophotometric determination of molybdenum (VI). The molybdenum (VI) is collected as molybdate ion on a column of chitin in weak acidic medium which is easily eluted with a small volume of 0.1 M ammonia buffer solution (pH 10). The molybdenum (VI) in the eluent is determined by bromopyrogallol red-Zephiramine method spectrophotometrically. Beer's law is obeyed over the concentration range of 0.1-0.8 mu g of molybdenum (VI) in 1 mi of eluent at 634 nm. The apparent molar absorptivity is 6 x 10(4) dm(3) mol(-1) cm(-1). The tolerance limits for WO42-, VO3-, CrO42- and Fe (III) is low, that is, 1-100 times that of molybdenum (VI), but some metal ions and common inorganic anions do not interfere in concentration range of 1000-5000 times that of molybdenum (VI). The present method can be applied to the determination of molybdenum (VI) in natural water samples. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:1473 / 1478
页数:6
相关论文
共 29 条