Microsystems for isolation and electrophysiological analysis of breast cancer cells from blood

被引:98
作者
Han, KH
Han, A
Frazier, AB
机构
[1] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[2] Texas A&M Univ, Dept Elect & Comp Engn, College Stn, TX 77843 USA
关键词
breast cancer cells (BCCs); electrical impedance spectroscopy (EIS); magnetophoresis;
D O I
10.1016/j.bios.2006.01.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper presents the development of a microsystem for separating suspended breast cancer cells in peripheral blood and for sorting them based on their electrophysiological characteristics. A continuous paramagnetic capture mode (PMC) magnetophoretic microseparator was utilized for the isolation of suspended breast cancer cells in peripheral blood based on the native magnetic properties of blood cells without any tagging such as with magnetic probes. A micro-electrical impedance spectroscopy (L-EIS) system was used as a downstream cell analysis tool to extract the pathological characteristics from the breast cancer cells. The system was fabricated on silicon and glass substrates utilizing microfabrication and stereolithography technologies. The experimental results of the PMC microseparator show that 94.8% of the breast cancer cells could be continuously separated out from a spiked blood sample with a 0.2 T external magnetic flux. The electrical impedances of human breast cancer cell lines of different pathological stages (MCF-7, MDA-MB-231, and MDA-MB-435) were measured using mu-EIS and compared to those of normal human breast tissue cell line MCF-10A. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1907 / 1914
页数:8
相关论文
共 62 条
[1]   Tumor cells circulate in the peripheral blood of all major carcinomas but not in healthy subjects or patients with nonmalignant diseases [J].
Allard, WJ ;
Matera, J ;
Miller, MC ;
Repollet, M ;
Connelly, MC ;
Rao, C ;
Tibbe, AGJ ;
Uhr, JW ;
Terstappen, LWMM .
CLINICAL CANCER RESEARCH, 2004, 10 (20) :6897-6904
[2]  
[Anonymous], 2002, MOL BASIS HUMAN CANC
[3]   DIELECTRIC MEASUREMENT OF A SINGLE SUBMILLIMETER SIZE MICROCAPSULE [J].
ASAMI, K ;
ZHAO, KS .
COLLOID AND POLYMER SCIENCE, 1994, 272 (01) :64-71
[4]   Electric impedance spectroscopy using microchannels with integrated metal electrodes [J].
Ayliffe, HE ;
Frazier, AB ;
Rabbitt, RD .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1999, 8 (01) :50-57
[5]   DETERMINATION OF MAGNETIC-SUSCEPTIBILITY OF LOADED MICROORGANISMS IN BIO-MAGNETIC SEPARATION [J].
BAHAJ, AS ;
WATSON, JHP ;
ELLWOOD, DC .
IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (05) :3809-3811
[6]   SEPARATION OF HUMAN BREAST-CANCER CELLS FROM BLOOD BY DIFFERENTIAL DIELECTRIC AFFINITY [J].
BECKER, FF ;
WANG, XB ;
HUANG, Y ;
PETHIG, R ;
VYKOUKAL, J ;
GASCOYNE, PRC .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (03) :860-864
[7]   Impedance spectra of tumour tissue in comparison with normal tissue; A possible clinical application for electrical impedance tomography [J].
Blad, B ;
Baldetorp, B .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 :A105-A115
[8]   An ultrasensitive tumor enriched flow-cytometric assay for detection of isolated tumor cells in bone marrow of patients with breast cancer [J].
Cabioglu, V ;
Igci, A ;
Yildirim, EO ;
Aktas, E ;
Bilgic, S ;
Yavuz, E ;
Muslumanoglu, M ;
Bozfakioglu, Y ;
Kecer, M ;
Ozmen, V ;
Deniz, G .
AMERICAN JOURNAL OF SURGERY, 2002, 184 (05) :414-417
[9]   DIELECTRIC-PROPERTIES OF FEMALE HUMAN BREAST-TISSUE MEASURED INVITRO AT 3.2 GHZ [J].
CAMPBELL, AM ;
LAND, DV .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :193-210
[10]  
COIN JT, 1979, J BIOL CHEM, V254, P1178