Advantages of pentafluorophenylpropyl stationary phase over conventionial C18 stationary phase - Application to analysis of triamcinolone acetonide

被引:15
作者
Havlikova, Lucie [1 ]
Matysova, Ludmila [1 ]
Hajkova, Renata [1 ]
Satinsky, Dalibor [1 ]
Solich, Petr [1 ]
机构
[1] Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Hradec Kralove 50005, Czech Republic
关键词
degradation product; C18; columns; HPLC; pentafluorophenylpropyl stationary phase; triamcinolone acetonide;
D O I
10.1016/j.talanta.2008.03.048
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A pentafluorophenylpropyl (PFPP) stationary phase was for the first time tested for the simultaneous determination of triamcinolone acetonide, its degradation product triamcinolone and two preservatives, methylparaben, and propylparaben. A new simple isocratic reversed phase HPLC method with UV detection, using estradiol hemihydrate as an internal standard, has been developed and validated. Chromatography was performed on a Discovery HS F5 column (150 mm x 4.6 mm, 5 mu m) using a binary mobile phase composed of acetonitrile and water 45:55 (v:v). The flow-rate was 0.6 mL/min, the column temperature 25 degrees C and the UV detection was accomplished at 240 nm. The chromatography results using PFPP stationary phase were compared with those obtained using conventional C18 columns. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:597 / 601
页数:5
相关论文
共 18 条
[1]
Rational method development strategies on a fluorinated liquid chromatography stationary phase: Mobile phase ion concentration and temperature effects on the separation of ephedrine alkaloids [J].
Bell, DS ;
Cramer, HM ;
Jones, AD .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1095 (1-2) :113-118
[2]
Solute attributes and molecular interactions contributing to "U-shape" retention on a fluorinated high-performance liquid chromatography stationary phase [J].
Bell, DS ;
Jones, AD .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1073 (1-2) :99-109
[3]
High-performance liquid chromatographic determination of acetyl-11-keto-α-boswellic acid, a novel pentacyclic triterpenoid, in plasma using a fluorinated stationary phase and photodiode array detection:: Application in pharmacokinetic studies [J].
Büchele, B ;
Zugmaier, W ;
Genze, F ;
Simmet, T .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 829 (1-2) :144-148
[4]
Quantitative analysis of s-adenosylmethionine and s-adenosylhomocysteine in neurulation-stage mouse embryos by liquid chromatography tandem mass spectrometry [J].
Burren, Katie A. ;
Mills, Kevin ;
Copp, Andrew J. ;
Greene, Nicholas D. E. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (01) :112-118
[5]
Council of Europe, 2007, EUR PHARM, P72
[6]
Chromatographic classification and comparison of commercially available reversed-phase liquid chromatographic columns using principal component analysis [J].
Euerby, M ;
Petersson, P .
JOURNAL OF CHROMATOGRAPHY A, 2003, 994 (1-2) :13-36
[7]
Chromatographic classification and comparison of commercially available perfluorinated stationary phases for reversed-phase liquid chromatography using Principal Component Analysis [J].
Euerby, MR ;
McKeown, AP ;
Petersson, P .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (3-4) :295-306
[8]
KAZACHEVICH Z, 2008, TXB HIGH PERFORMANCE
[9]
Determination of methylparaben, propylparaben, triamcinolone acetonide and its degradation product in a topical cream by RP-HPLC [J].
Matysová, L ;
Hájková, R ;
Sícha, J ;
Solich, P .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (04) :440-443
[10]
Optimized stationary phases for the high-performance liquid chromatography-electrospray ionization mass spectrometric analysis of basic pharmaceuticals [J].
Needham, SR ;
Brown, PR ;
Duff, K ;
Bell, D .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :159-170