Improvements in the in-beam gamma-ray spectroscopy provided by an ancillary detector coupled to a Ge gamma-spectrometer: The DIAMANT-EUROGAM II example

被引:80
作者
Scheurer, JN
Aiche, M
Aleonard, MM
Barreau, G
Bourgine, F
Boivin, D
Cabaussel, D
Chemin, JF
Doan, TP
Goudour, JP
Harston, M
Brondi, A
LaRana, G
Moro, R
Vardaci, E
Curien, D
机构
[1] IST NAZL FIS NUCL,I-80125 NAPLES,ITALY
[2] UNIV NAPLES,DIPARTIMENTO SCI FIS,I-80125 NAPLES,ITALY
[3] CTR RECH NUCL,IN2P3,F-67037 STRASBOURG 2,FRANCE
关键词
charged particle spectrometer; scintillation detector; gamma ray spectroscopy; Doppler shift correction;
D O I
10.1016/S0168-9002(96)01038-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For the first time the 4 pi gamma-ray spectrometer EUROGAM II has been coupled to a 4 pi light charged particle detector array, DIAMANT, during a test experiment on the reaction S-32 + Ni-58 at 120 MeV beam energy. A very large improvement in the peak-to-background ratio of the gamma-spectra has been found when EUROGAM II is triggered by DIAMANT to select an exit channel. A simple algebra has been developed which provides theoretical estimates in good agreement with these experimental results. It is demonstrated that, depending on both the gamma-spectrometer and ancillary detector performances, much better peak-to-background can be obtained by such a coupling. For the same peak-to-background ratio, the use of an ancillary detector allows for a lower gamma-ray coincidence level and therefore improves the statistics. Ways to select the most appropriate ancillary detector an given. The ability of the ancillary detector to provide a total Doppler shift correction is crucial for the improvement of the peak-to-background ratio.
引用
收藏
页码:501 / 510
页数:10
相关论文
共 10 条
[1]  
AICHE M, UNPUB NUCL INSTR MET
[2]   EUROBALL - LARGE GAMMA-RAY SPECTROMETERS THROUGH EUROPEAN COLLABORATIONS [J].
BECK, FA .
PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, 1992, 28 :443-461
[3]  
*EUR GAMMR FAC, 1992, EUROGALL 3
[4]  
*EUROGAZM, 1990, INT EUROGAM COLL REP
[5]   HEAVY-ION IN-BEAM STUDIES OF THE NUCLEUS NB-87 [J].
JUNGCLAUS, A ;
LIEB, KP ;
GROSS, CJ ;
HEESE, J ;
RUDOLPH, D ;
BLUMENTHAL, DJ ;
CHOWDHURY, P ;
ENNIS, PJ ;
LISTER, CJ ;
WINTER, C ;
EBERTH, J ;
SKODA, S ;
BENTLEY, MA ;
GELLETLY, W ;
VARLEY, BJ .
ZEITSCHRIFT FUR PHYSIK A-HADRONS AND NUCLEI, 1991, 340 (02) :125-139
[6]  
MITARAI S, 1903, Z PHYS A, V344, P405
[7]  
SCHEURER JN, 1993, INT C FUT NUCL SPECT, P371
[8]  
SCHEURER JN, UNPUB
[9]   CORRECTION OF DOPPLER BROADENING OF GAMMA-RAY LINES INDUCED BY PARTICLE-EMISSION IN HEAVY-ION-INDUCED FUSION-EVAPORATION REACTIONS [J].
SEWERYNIAK, D ;
NYBERG, J ;
FAHLANDER, C ;
JOHNSON, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 340 (02) :353-363
[10]  
TWIN PJ, 1986, PHYS REV LETT, V57, P811, DOI 10.1103/PhysRevLett.57.811