Factors associated with successful implantation of nonthoracotomy defibrillation lead systems

被引:16
作者
Schwartzman, D
Concato, J
Ren, JF
Callans, DJ
Gottlieb, CD
Preminger, MW
Marchlinski, FE
机构
[1] YALE UNIV, SCH MED, CLIN EPIDEMIOL UNIT, NEW HAVEN, CT 06520 USA
[2] W HAVEN VET AFFAIRS MED CTR, NEW HAVEN, CT USA
关键词
D O I
10.1016/S0002-8703(96)90087-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Two hundred forty-three consecutive patients underwent attempted implantation of nonthoracotomy defibrillation lead (NTL) systems. The importance of clinical and lead-related factors were analyzed regarding their relation with implantation failure caused by an unacceptably high defibrillation threshold (DTT). Overall, 33 (14%) of 243 patients failed NTL implantation. Patients undergoing attempted implantation of NTL systems with monophasic shock waveforms (monophasic group, n = 145) had an incidence of failed implantation of 22% (n = 32) versus an incidence of 1% (n = 1) among patients undergoing attempted implantation by using biphasic shock waveforms (biphasic group, n = 98; odds ratio, 26.9; p<0.001). The incidence of success and simplicity of implantation of NTL systems was markedly improved in patients undergoing NTL implantation by using biphasic shock waveforms. Clinical factors could be used to stratify patients in the monophasic group for their risk of implantation failure. In the biphasic group, no clinical factor could be correlated with a low DFT with a fully endovascular system.
引用
收藏
页码:1127 / 1136
页数:10
相关论文
共 29 条
[1]  
BLOCK M, 1992, Journal of the American College of Cardiology, V19, p243A
[2]   DETERMINANTS OF SUCCESSFUL NONTHORACOTOMY CARDIOVERTER-DEFIBRILLATOR IMPLANTATION - EXPERIENCE IN 101 PATIENTS USING 2 DIFFERENT LEAD SYSTEMS [J].
BROOKS, R ;
GARAN, H ;
TORCHIANA, D ;
VLAHAKES, GJ ;
JACKSON, G ;
NEWELL, J ;
MCGOVERN, BA ;
RUSKIN, JN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (07) :1835-1842
[3]   RELATIONSHIP OF LEFT-VENTRICULAR MASS TO DEFIBRILLATION THRESHOLD FOR THE IMPLANTABLE DEFIBRILLATOR - A COMBINED CLINICAL AND ANIMAL STUDY [J].
CHAPMAN, PD ;
SAGAR, KB ;
WETHERBEE, JN ;
TROUP, PJ .
AMERICAN HEART JOURNAL, 1987, 114 (02) :274-278
[4]   PROBLEMS OF COMORBIDITY IN MORTALITY AFTER PROSTATECTOMY [J].
CONCATO, J ;
HORWITZ, RI ;
FEINSTEIN, AR ;
ELMORE, JG ;
SCHIFF, SF .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 267 (08) :1077-1082
[5]  
EHRLICH S, 1992, Journal of the American College of Cardiology, V19, p365A
[6]  
FEINSTEIN AR, 1990, MEDICINE, V69, P1
[7]   SUPERIORITY OF BIPHASIC SHOCKS IN THE DEFIBRILLATION OF DOGS BY EPICARDIAL PATCHES AND CATHETER ELECTRODES [J].
FLAKER, GC ;
SCHUDER, JC ;
MCDANIEL, WC ;
STOECKLE, H ;
DBEIS, M .
AMERICAN HEART JOURNAL, 1989, 118 (02) :288-291
[8]   NONTHORACOTOMY DEFIBRILLATOR IMPLANTATION - A SINGLE-CENTER EXPERIENCE WITH 200 PATIENTS [J].
HAMMEL, D ;
SCHELD, HH ;
BLOCK, M ;
BREITHARDT, G .
ANNALS OF THORACIC SURGERY, 1994, 58 (02) :321-327
[9]  
Hosmer D., 1989, APPL LOGISTIC REGRES
[10]   A NEW PROGNOSTIC STAGING SYSTEM FOR THE ACQUIRED IMMUNODEFICIENCY SYNDROME [J].
JUSTICE, AC ;
FEINSTEIN, AR ;
WELLS, CK .
NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (21) :1388-1393