Incomplete neointimal coverage of sirolimus-eluting stents - Angioscopic findings

被引:340
作者
Kotani, Jun-ichi [1 ]
Awata, Masaki
Nanto, Shinsuke
Uematsu, Masaaki
Oshima, Fusako
Minamiguchi, Hitoshi
Mintz, Gary S.
Nagata, Seiki
机构
[1] Kansai Rosai Hosp, Div Cardiovasc, Amagasaki, Hyogo, Japan
[2] Cardiovasc Res Fdn, New York, NY USA
关键词
D O I
10.1016/j.jacc.2005.11.092
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The goal of this study was to use angioscopy to investigate the amount of neointimal coverage after sirolimus-eluting stent (SES) implantation. BACKGROUND Sirolimus-eluting stents reduce intimal hyperplasia. METHODS We used angioscopy to evaluate 37 consecutive stented coronary artery lesions (15 SES and 22 bare-metal stents [BMS]) in 25 patients (18 men, 7 women) at 3 to 6 months after stent implantation. Angioscopic evaluation focused on: 1) neointimal coverage of stent struts, and 2) the existence of thrombi. The degree of neointimal coverage was classified as grade 0 when there was no neointimal coverage (similar to immediately after the implantation); grade 1 when stent struts bulged into the lumen, but were covered and still translucently visible; grade 2 when stent struts were visible but not clearly seen (not translucent); and grade 3 when stent struts were not visible because they were embedded in the neointima. RESULTS Thrombi were identified in eight stented segments, tended to be more common with SES (p = 0.14), but were not seen on angiography. Three of the 15 SES (20%) had grade 0 neointimal coverage, and only 2 SES (13.3%) had complete coverage (grades 2/3). In contrast, all 22 BMS showed complete intimal coverage (grades 2/3). Thrombi were more common in stents with incomplete neointimal coverage (p = 0.09). CONCLUSIONS The SES had incomplete neointimal coverage three to six months after implantation, and this was associated with subclinical thrombus formation. (J Am Coll Cardiol 2006;47:2108-11) (c) 2006 by the American College of Cardiology Foundation.
引用
收藏
页码:2108 / 2111
页数:4
相关论文
共 17 条
  • [1] Remodeling of in-stent neointima, which became thinner and transparent over 3 years - Serial angiographic and angioscopic follow-up
    Asakura, M
    Ueda, Y
    Nanto, S
    Hirayama, A
    Adachi, T
    Kitakaze, M
    Hori, M
    Kodama, K
    [J]. CIRCULATION, 1998, 97 (20) : 2003 - 2006
  • [2] Time course of stent endothelialization after intravascular radiation therapy in rabbit iliac arteries
    Cheneau, E
    John, MC
    Fournadjiev, J
    Chan, RC
    Kim, HS
    Leborgne, L
    Pakala, R
    Yazdi, H
    Ajani, AE
    Virmani, R
    Waksman, R
    [J]. CIRCULATION, 2003, 107 (16) : 2153 - 2158
  • [3] Pathological mechanisms of fatal late coronary stent thrombosis in humans
    Farb, A
    Burke, AP
    Kolodgie, FD
    Virmani, R
    [J]. CIRCULATION, 2003, 108 (14) : 1701 - 1706
  • [4] Five-year clinical follow-up after intracoronary radiation - Results of a randomized clinical trial
    Grise, MA
    Massullo, V
    Jani, S
    Popma, JJ
    Russo, RJ
    Schatz, RA
    Guarneri, EM
    Steuterman, S
    Cloutier, DA
    Leon, MB
    Tripuraneni, P
    Teirstein, PS
    [J]. CIRCULATION, 2002, 105 (23) : 2737 - 2740
  • [5] Sirolimus-eluting stent implanted in human coronary artery for 16 months - Pathological findings
    Guagliumi, G
    Farb, A
    Musumeci, G
    Valsecchi, O
    Tespili, M
    Motta, T
    Virmani, R
    [J]. CIRCULATION, 2003, 107 (09) : 1340 - 1341
  • [6] EXPERIMENTAL VALIDATION OF GEOMETRIC AND DENSITOMETRIC CORONARY MEASUREMENTS ON THE NEW-GENERATION CARDIOVASCULAR ANGIOGRAPHY ANALYSIS SYSTEM (CAAS-II)
    HAASE, J
    ESCANED, J
    VANSWIJNDREGT, EM
    OZAKI, Y
    GRONENSCHILD, E
    SLAGER, CJ
    SERRUYS, PW
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 30 (02): : 104 - 114
  • [7] Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents
    Iakovou, I
    Schmidt, T
    Bonizzoni, E
    Ge, L
    Sangiorgi, GM
    Stankovic, G
    Airoldi, F
    Chieffo, A
    Montorfano, M
    Carlino, M
    Michev, I
    Corvaja, N
    Briguori, C
    Gerckens, U
    Grube, E
    Colombo, A
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (17): : 2126 - 2130
  • [8] Stent thrombosis after successful sirolimus-eluting stent implantation
    Jeremias, A
    Sylvia, B
    Bridges, J
    Kirtane, AJ
    Bigelow, B
    Pinto, DS
    Ho, KKL
    Cohen, DJ
    Garcia, LA
    Cutlip, DE
    Carrozza, JP
    [J]. CIRCULATION, 2004, 109 (16) : 1930 - 1932
  • [9] Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy
    McFadden, EP
    Stabile, E
    Regar, E
    Cheneau, E
    Ong, ATL
    Kinnaird, T
    Suddath, WO
    Weissman, NJ
    Torguson, R
    Kent, KM
    Pichard, AD
    Satler, LF
    Waksman, R
    Serruys, PW
    [J]. LANCET, 2004, 364 (9444) : 1519 - 1521
  • [10] Intravascular ultrasound assessment of neointima distribution and the length of stent that was free of intravascular ultrasound-detectable intimal hyperplasia in paclitaxel-eluting stents
    Mintz, GS
    Hong, MK
    Raizner, AE
    Lee, CW
    Kim, JJ
    Escolar, E
    Fearnot, NE
    Park, SW
    Park, SJ
    Weissman, NJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (01) : 107 - 109