Towards the self-calibration of a multiview radiographic imaging system for the 3D reconstruction of the human spine and rib cage

被引:30
作者
Cheriet, F
Dansereau, J
Petit, Y
Aubin, CÉ
Labelle, H
De Guise, JA
机构
[1] Hop St Justine, Ctr Rech, Montreal, PQ H3T 1C5, Canada
[2] Ecole Polytech, Montreal, PQ H3C 3A7, Canada
[3] Ecole Technol Super, Montreal, PQ H3C 1K3, Canada
关键词
self-calibration; 3D reconstruction; multiview radiographic images; idiopathic scoliosis;
D O I
10.1142/S0218001499000434
中图分类号
TP18 [人工智能理论];
学科分类号
081104 [模式识别与智能系统]; 0812 [计算机科学与技术]; 0835 [软件工程]; 1405 [智能科学与技术];
摘要
The main objective of this study was to develop a 3D reconstruction technique of the spine and rib cage of idiopathic scoliotic patients using the self-calibration of the imaging system. The proposed approach computes the intrinsic and extrinsic parameters of the radiographic setup with respect to the global coordinate system used at Ste-Justine Hospital. Our approach determines an optimal estimate of the geometrical parameters of the imaging system from a nonlinear minimization of the mean square distance between the observed and analytical projections of a set of matched points identified on a pair of radiographic views. The accuracy of the optimal estimate for the intrinsic parameters was significantly improved when geometric knowledge such as the known length of detectable straight bars is incorporated as a set of equality constraints in the optimization process. Furthermore, in order to retrieve the 3D structure of interest in the global coordinate system, a reference plane including the origin of the global coordinate system is specified. Computer simulations were performed to evaluate the self-calibration procedure and to determine the minimum knowledge required to obtain an accurate 3D reconstruction for clinical applications. An in vitro validation on real images of a dry cadaveric human spine showed that the method is feasible and reaches the expected accuracy.
引用
收藏
页码:761 / 779
页数:19
相关论文
共 29 条
[1]
EFFECT OF RADIOGRAPHIC LANDMARK IDENTIFICATION ERRORS ON THE ACCURACY OF 3-DIMENSIONAL RECONSTRUCTION OF THE HUMAN SPINE [J].
ANDRE, B ;
DANSEREAU, J ;
LABELLE, H .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1992, 30 (06) :569-575
[2]
OPTIMIZED VERTICAL STEREO BASE RADIOGRAPHIC SETUP FOR THE CLINICAL 3-DIMENSIONAL RECONSTRUCTION OF THE HUMAN SPINE [J].
ANDRE, B ;
DANSEREAU, J ;
LABELLE, H .
JOURNAL OF BIOMECHANICS, 1994, 27 (08) :1023-&
[3]
AUBIN CE, 1997, MED BIOL ENG COMPUT, V38, P1
[4]
A nonlinear Gauss-Seidel algorithm for noncoplanar and coplanar camera calibration with convergence analysis [J].
Chatterjee, C ;
Roychowdhury, VP ;
Chong, EKP .
COMPUTER VISION AND IMAGE UNDERSTANDING, 1997, 67 (01) :58-80
[5]
CHERIET F, 1994, P SOC PHOTO-OPT INS, V2354, P279, DOI 10.1117/12.189095
[6]
Cheriet F, 1999, STUD HEALTH TECHNOL, V59, P187
[7]
CHERIET F, 1996, THESIS U MONTREAL
[8]
MEASUREMENTS OF THE 3-DIMENSIONAL SHAPE OF THE RIB CAGE [J].
DANSEREAU, J ;
STOKES, IAF .
JOURNAL OF BIOMECHANICS, 1988, 21 (11) :893-901
[9]
DANSEREAU J, 1990, 16TH C CAN SOC MECH, V2, P61
[10]