Predictions of reversed-phase gradient elution LC separations supported by QSRR

被引:13
作者
Baczek, Tomasz [1 ,2 ]
Bodzioch, Karolina [1 ]
Michalska, Elzbieta [1 ]
Kaliszan, Roman [1 ]
机构
[1] Med Univ Gdansk, Dept Biopharmaceut & Pharmacodynam, Hallera 107, PL-80416 Gdansk, Poland
[2] Nicholas Copernicus Univ Torun, Coll Med, Dept Med Chem, PL-85094 Bydgoszcz, Poland
关键词
column liquid chromatography; quantitative structure-retention relationships; linear solvent strength model; prediction of retention; gradient elution;
D O I
10.1365/s10337-008-0674-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Previous studies demonstrated that quantitative structure-retention relationships (QSRR) combined with the linear solvent strength (LSS) model allow for prediction of gradient reversed-phase liquid chromatography retention time for any analyte of a known molecular structure under defined LC conditions. A QSRR model derived at the selected gradient time and at the same gradient time was tested. The aim the present study was to evaluate the accuracy of QSRR predictions used during the predictions of LC gradient retention times with variable gradient times. For this purpose, predictions of retention times at two gradient times were used to find the optimal, different gradient times. In the first step, experimental retention data for the model set of analytes were used to derive appropriate QSRR models at two gradient times. These QSRR models were further used to predict gradient retention times for another set of testing analytes at the two selected above gradient times. Then, applying linear solvent-strength (LSS) theory, the predicted retention times for test analytes were used to find other optimal gradient times for those analytes. Satisfactory predictions of gradient retention times for test analytes were obtained at gradient times different from those applied for model analytes.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 10 条
[1]   Comparative characteristics of HPLC columns based on quantitative structure-retention relationships (QSRR) and hydrophobic-subtraction model [J].
Baczek, T ;
Kaliszan, R ;
Novotná, K ;
Jandera, P .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1075 (1-2) :109-115
[2]  
Baczek T, 2003, J CHROMATOGR A, V987, P29
[3]  
Baczek T, 2002, J CHROMATOGR A, V962, P41
[4]  
BACZEK T, 2001, LC GC EUR, V14, P304
[5]   Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time III. Improving the accuracy of computer simulation [J].
Dolan, JW ;
Snyder, LR ;
Wolcott, RG ;
Haber, P ;
Baczek, T ;
Kaliszan, R ;
Sander, LC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 857 (1-2) :41-68
[6]   Determination of selectivity differences for basic compounds in gradient reverse phase high performance liquid chromatography under high pH conditions by partial least squares modelling [J].
Fornal, Emilia ;
Borman, Phil ;
Luscombe, Christopher .
ANALYTICA CHIMICA ACTA, 2006, 570 (02) :267-276
[7]   Prediction of gradient retention from the linear solvent strength (LSS) model, quantitative structure-retention relationships (QSRR), and artificial neural networks (ANN) [J].
Kaliszan, R ;
Baczek, T ;
Bucinski, A ;
Buszewski, B ;
Sztupecka, M .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (3-4) :271-282
[8]  
Kaliszan R., 1997, STRUCTURE RETENTION
[9]  
Snyder LR, 1998, ADV CHROMATOGR, V38, P115
[10]   The hydrophobic-subtraction model of reversed-phase column selectivity [J].
Snyder, LR ;
Dolan, JW ;
Carr, PW .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1060 (1-2) :77-116