共 23 条
Is the Computer-Aided Detection Scheme for Lung Nodule Also Useful in Detecting Lung Cancer?
被引:17
作者:
Goo, Jin Mo
[1
,2
]
Kim, Hyae Young
[3
]
Lee, Jeong Won
[4
]
Lee, Hyun Ju
[1
,2
]
Lee, Chang Hyun
[1
,2
]
Lee, Kyung Won
[5
]
Kim, Tae Jung
[5
]
Lim, Kun Young
[3
]
Park, Seong Ho
[6
]
Bae, Kyongtae T.
[7
]
机构:
[1] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul 110744, South Korea
[3] Natl Canc Ctr, Res Inst & Hosp, Goyang, Gyeonggi, South Korea
[4] Elect & Telecommun Res Inst, IT BT Grp, Taejon 305606, South Korea
[5] Seoul Natl Univ, Bundang Hosp, Dept Radiol, Seoul 110744, South Korea
[6] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul, South Korea
[7] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15260 USA
关键词:
computer-aided diagnosis;
lung nodules;
lung cancer;
multidetector-row CT;
D O I:
10.1097/RCT.0b013e318146261c
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 [临床医学];
100207 [影像医学与核医学];
1009 [特种医学];
摘要:
Objective: To evaluate the impact of a computer-aided diagnosis (CAD) system on the performance of observers for the detection of both lung nodules and lung cancers. Materials and Methods: One hundred fifty computed tomographic scans were evaluated. Database included 23 lung cancers (long diameter < 20 mm), nodules stable for at least 2 years, and normal cases. Five chest radiologists and 5 radiology residents each independently recorded the locus of each nodule candidate and assigned a confidence score for the likelihood of nodule and malignancy without CAD; then, the interpretation was repeated with the use of CAD. A consensus panel of 2 chest radiologists served as a reference standard for the nodules. Histological continuation was a reference standard for the cancers. The performances of the observers for the detection of nodules and cancer with and without CAD were compared using jackknife free-response receiver operating characteristic analysis. Results: The performance of detecting lung nodules was increased significantly with CAD for all radiologists and subgroups (P < 0.01). Although the overall performance of detecting lung cancers was not affected significantly with the use of CAD (P > 0.05), 4 lung cancers missed by 3 residents on their initial observation were additionally detected with CAD. Eighteen of 23 lung cancers were detected by CAD itself. Conclusions: The overall radiologists' performance of detecting lung nodules was improved significantly with the use of CAD whereas no statistical significance was observed for the detection of lung cancers. The use of CAD, however, contributed to the detection of additional lung cancers for less experienced readers.
引用
收藏
页码:570 / 575
页数:6
相关论文

