Estimation of glomerular filtration rate with Tc-99(m)-DTPA: A comparative assessment of simplified methods

被引:15
作者
Galli, G [1 ]
Rufini, V [1 ]
Vellante, C [1 ]
DErrico, G [1 ]
Piraccini, R [1 ]
机构
[1] UNIV CATTOLICA SACRO CUORE, DEPT NUCL MED, I-00168 ROME, ITALY
关键词
D O I
10.1097/00006231-199707000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In 40 adult patients undergoing gamma camera renography, glomerular filtration rate (GFR) was measured using simplified Tc-99(m)-DTPA methods (i.e. a personal modification of the 'slope' method which does not require dose calibration, Gates' method and Carlsen's method) and compared to reference results (obtained using Sapirstein's formula and Russell's two-sample method with Cr-51-EDTA). Estimation of Gm from plasma creatinine (the Cockroft-Gault formula) was also carried out. Bias and imprecision of the simplified estimates were determined by the Bland-Altman method. The GFR values of the 'slope' method correlated best with the reference values (R-2 = 0.88, S.E.E. = 11.3 ml min(-1)). Correlation of the two methods based on external determination with the gamma camera was net better at estimating GFR, than that from plasma creatinine. Moreover, Gates' method underestimated GFR at all levels between 25 and 150 ml min(-1), while Carlsen's method overestimated at low levels and underestimated at high levels. The bias was as follows (ml): Cockroft-Gault 2.4; 'slope' -4.1; Carlsen 7.5; Gates 16.7. The imprecision was as follows (ml): 'slope' 11.8; Cockroft-Gault 16.4; Carlsen 20.5; Gates 22.8. We conclude that our modification of the slope method correlated best with the reference results, and would appear suitable for routine practice because of the small error involved. When performing sequential renal scintigraphy, it can also be used for a quick check of dubious data based on gamma camera methods.
引用
收藏
页码:634 / 641
页数:8
相关论文
共 25 条
[1]   ESTIMATION OF GLOMERULAR-FILTRATION RATE USING CHROMIUM-51 ETHYLENE DIAMINE TETRAACETIC ACID AND TC-99M DIETHYLENE TRIAMINE PENTA-ACETIC ACID [J].
BIGGI, A ;
VIGLIETTI, A ;
FARINELLI, MC ;
BONADA, C ;
CAMUZZINI, G .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (06) :532-536
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Blaufox MD, 1996, J NUCL MED, V37, P1883
[4]  
CARLSEN O, 1995, NUCL MED COMMUN, V16, P405
[5]  
CHRISTENSEN AB, 1986, CLIN PHYSIOL, V6, P579
[6]   PREDICTION OF CREATININE CLEARANCE FROM SERUM CREATININE [J].
COCKCROFT, DW ;
GAULT, MH .
NEPHRON, 1976, 16 (01) :31-41
[7]  
DURAND E, 1995, NUCL MED COMMUN, V16, P405
[8]   COMPARATIVE-ASSESSMENT OF TECHNIQUES FOR ESTIMATION OF GLOMERULAR-FILTRATION RATE WITH TC-99M-DTPA [J].
FAWDRY, RM ;
GRUENEWALD, SM ;
COLLINS, LT ;
ROBERTS, AJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1985, 11 (01) :7-12
[9]  
FELDMANN U, 1981, J CLIN CHEM CLIN BIO, V19, P121
[10]  
FLEMING JS, 1987, EUR J NUCL MED, V13, P250, DOI 10.1007/BF00252602