Reproducibility of in vivo carotid intima-media thickness measurements - A review

被引:316
作者
Kanters, SDJM
Algra, A
vanLeeuwen, MS
Banga, JD
机构
[1] UNIV UTRECHT HOSP,DEPT INTERNAL MED,NL-3508 GA UTRECHT,NETHERLANDS
[2] UNIV UTRECHT HOSP,DEPT CLIN EPIDEMIOL,NL-3508 GA UTRECHT,NETHERLANDS
[3] UNIV UTRECHT HOSP,DEPT RADIOL,NL-3508 GA UTRECHT,NETHERLANDS
关键词
carotid arteries; observer variation; ultrasonics;
D O I
10.1161/01.STR.28.3.665
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background The early phase of atherosclerosis can be studied by two-dimensional B-mode ultrasonography. Measurements of the combined thickness of the carotid intima and media are currently used as intermediate outcome in clinical trials. Comparison of results between studies is difficult because of the different methods of image acquisition and analysis used. We review these methods and the reported reproducibility of intima-media thickness (IMT) measurements. Summary of Review Articles were collected using the MEDLINE literature search system and the references in the selected articles. Literature concerning human in vivo IMT measurements published in the English language in the period 1991 through 1995 was reviewed. A description of the methods of measuring IMT to determine intraobserver and/or interobserver variability was a prerequisite for inclusion. Twenty-three studies were included. Best reproducibility was found when measuring the mean IMT in the common carotid artery in more than one direction. Conclusions We conclude that a consensus concerning the assessment of IMT is urgently needed. Variability of IMT measurements is lowest when determining the mean thickness in the common carotid artery in different directions.
引用
收藏
页码:665 / 671
页数:7
相关论文
共 48 条
[1]   CAROTID INTIMA-MEDIA THICKNESS IS ONLY WEAKLY CORRELATED WITH THE EXTENT AND SEVERITY OF CORONARY-ARTERY DISEASE [J].
ADAMS, MR ;
NAKAGOMI, A ;
KEECH, A ;
ROBINSON, J ;
MCCREDIE, R ;
BAILEY, BP ;
BENFREEDMAN, S ;
CELERMAJER, DS .
CIRCULATION, 1995, 92 (08) :2127-2134
[2]  
[Anonymous], 1991, J Neuroimaging, V1, P68
[3]   COMMON CAROTID INTIMA-MEDIA THICKNESS MEASUREMENT - A METHOD TO IMPROVE ACCURACY AND PRECISION [J].
BALDASSARRE, D ;
WERBA, JP ;
TREMOLI, E ;
POLI, A ;
PAZZUCCONI, F ;
SIRTORI, CR .
STROKE, 1994, 25 (08) :1588-1592
[4]  
BELCARO G, 1993, PANMINERVA MED, V35, P75
[5]  
Berglund G L, 1994, J Intern Med, V236, P551
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   BENEFICIAL-EFFECTS OF COLESTIPOL-NIACIN THERAPY ON THE COMMON CAROTID-ARTERY - 2-YEAR AND 4-YEAR REDUCTION OF INTIMA-MEDIA THICKNESS MEASURED BY ULTRASOUND [J].
BLANKENHORN, DH ;
SELZER, RH ;
CRAWFORD, DW ;
BARTH, JD ;
LIU, CR ;
LIU, CH ;
MACK, WJ ;
ALAUPOVIC, P .
CIRCULATION, 1993, 88 (01) :20-28
[8]  
BOND MG, 1989, AM J MED, V86, P33
[9]   REPRODUCIBILITY OF CAROTID VESSEL WALL THICKNESS MEASUREMENTS - THE ROTTERDAM STUDY [J].
BOTS, ML ;
MULDER, PGH ;
HOFMAN, A ;
VANES, GA ;
GROBBEE, DE .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1994, 47 (08) :921-930
[10]   COMMON CAROTID INTIMA-MEDIA THICKNESS AND LOWER-EXTREMITY ARTERIAL ATHEROSCLEROSIS - THE ROTTERDAM STUDY [J].
BOTS, ML ;
HOFMAN, A ;
GROBBEE, DE .
ARTERIOSCLEROSIS AND THROMBOSIS, 1994, 14 (12) :1885-1891