A contact model with ingrowth control for bone remodelling around cementless stems

被引:72
作者
Fernandes, PR [1 ]
Folgado, J
Jacobs, C
Pellegrini, V
机构
[1] Inst Super Tecn, IDMEC, Lisbon, Portugal
[2] Stanford Univ, Dept Mech Engn, Biomech Engn Div, Stanford, CA 94305 USA
[3] Penn State Univ, Dept Orthopaed, MRL, Hershey, PA USA
关键词
bone remodeling; bone ingrowth; hip arthroplasty; interface conditions; finite element analysis;
D O I
10.1016/S0021-9290(01)00204-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This work presents a computational model for bone remodelling around cementless stems. The problem is formulated as a material optimisation problem considering the bone and stem surfaces to be in contact. To emphasise the behaviour of the bone/stem interface, the computer model detects the existence of bone ingrowth during the remodelling; consequently, the contact conditions are changed for a better interface simulation. The trabecular bone is modelled as a strictly orthotropic material with equivalent properties computed by homogenisation. The distribution of bone relative density is obtained by the minimisation of a function that considers both the bone structural stiffness and the biological cost associated with metabolic maintenance of bone tissue. The situation of multiple load conditions is considered. The remodelling law, obtained from the necessary conditions for an optimum, is derived analytically from the optimisation problem and solved numerically using a suitable finite element mesh. The formulation is applied to an implanted femur. Results of bone density and ingrowth distribution are obtained for different coating conditions. Bone ingrowth does not occur over the entire coated surfaces. Indeed, we observed regions where separation or high relative displacement occurs that preclude bone ingrowth attachment. This prediction of the model is consistent with clinical observations of bone ingrowth. Thus, this model, which detect bone ingrowth and allow modification of the interface conditions, are useful for analysis of existing stems as well as design optimisation of coating extent and location on such stems. Published by Elsevier Science Ltd.
引用
收藏
页码:167 / 176
页数:10
相关论文
共 21 条
[1]  
[Anonymous], 1998, US MAN VERS 5 8
[2]   AN APPROACH FOR TIME-DEPENDENT BONE MODELING AND REMODELING - THEORETICAL DEVELOPMENT [J].
BEAUPRE, GS ;
ORR, TE ;
CARTER, DR .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (05) :651-661
[3]   OPTIMIZATION OF THE STRAIN-ENERGY DENSITY IN LINEAR ANISOTROPIC ELASTICITY [J].
COWIN, SC .
JOURNAL OF ELASTICITY, 1994, 34 (01) :45-68
[4]  
ENGH CA, 1992, CLIN ORTHOP RELAT R, P13
[5]   POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55
[6]  
Fernandes P., 1999, Comput Methods Biomech Biomed Engin, V2, P125, DOI 10.1080/10255849908907982
[7]  
FERNANDES P, 1999, P 4 INT S COMP METH
[8]   PREPROCESSING AND POSTPROCESSING FOR MATERIALS BASED ON THE HOMOGENIZATION METHOD WITH ADAPTIVE FINITE-ELEMENT METHODS [J].
GUEDES, JM ;
KIKUCHI, N .
COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 1990, 83 (02) :143-198
[9]  
HUISKES R, 1995, CLIN ORTHOP RELAT R, P64
[10]   EFFECTS OF POROUS COATING, WITH AND WITHOUT COLLAR SUPPORT, ON EARLY RELATIVE MOTION FOR A CEMENTLESS HIP-PROSTHESIS [J].
KEAVENY, TM ;
BARTEL, DL .
JOURNAL OF BIOMECHANICS, 1993, 26 (12) :1355-1368