First measurements of electron temperature and density with divertor Thomson scattering in radiative divertor discharges on DIII-D

被引:20
作者
Allen, SL
Hill, DN
Carlstrom, TN
Nilson, DG
Stockdale, R
Hsieh, CL
Petrie, TW
Leonard, AW
Ryutov, D
Porter, GD
Maingi, R
Wade, MR
Cohen, R
Nevins, W
Fenstermacher, ME
Wood, RD
Lasnier, CJ
West, WP
Brown, MD
机构
[1] LAWRENCE LIVERMORE NATL LAB,LIVERMORE,CA
[2] OAK RIDGE ASSOCIATED UNIV,OAK RIDGE,TN
[3] OAK RIDGE NATL LAB,OAK RIDGE,TN
关键词
DIII-D; plasma temperature diagnostic; detached plasma; poloidal divertor; divertor plasma; PROBE;
D O I
10.1016/S0022-3115(97)80106-7
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We have obtained the first measurements of n(e) and T-e in the DIII-D divertor region with a multi-pulse (20 Hz) divertor Thomson scattering (DTS) system. Eight measurement locations are distributed vertically up to 21 cm above the divertor plate. Two-dimensional distributions have been obtained by sweeping the divertor plasma across the DTS measurement location. Several operating modes have been studied, including Ohmic, L-mode, ELMing K-mode, and radiative divertor operation with puffing of D-2 and impurities. Mapping of the data to either the (L-pol, phi) or (R, Z) planes with the EFIT equilibrium is used to analyze the 2D profiles. We find that in ELMing H-mode: n(e), T-e, and P-e are relatively constant along field lines from the X-point to the divertor plate, especially near the separahix field line. With D, puffing, the DTS profiles indicate that T-e in a large part of divertor region below the X-point is dramatically reduced from similar to 30-40 eV in ELMing H-mode to 1-2 eV. This results in a fairly uniform low-T-e divertor, with an increased electron density in the range of 2 to 4 x 10(20) m(-3). Detailed comparisons of the spatial profiles of n(e), T-e, and electron pressure P-e, are presented for several operating modes. In addition, these data are compared with initial calculations from the UEDGE fluid code.
引用
收藏
页码:595 / 601
页数:7
相关论文
共 14 条
[1]   DEVELOPMENT OF A RADIATIVE DIVERTOR FOR DIII-D [J].
ALLEN, SL ;
BROOKS, NH ;
CAMPBELL, RB ;
FENSTERMACHER, ME ;
HILL, DN ;
HYATT, AW ;
KNOLL, D ;
LASNIER, CJ ;
LAZARUS, EA ;
LEONARD, AW ;
LIPPMANN, SI ;
MAHDAVI, MA ;
MAINGI, R ;
MEYER, W ;
MOYER, RA ;
PETRIE, TW ;
PORTER, GD ;
RENSINK, ME ;
ROGNLIEN, TD ;
SCHAFFER, MJ ;
SMITH, JP ;
STAEBLER, GM ;
STAMBAUGH, RD ;
WEST, WP ;
WOOD, RD .
JOURNAL OF NUCLEAR MATERIALS, 1995, 220 :336-341
[2]   LANGMUIR PROBE ARRAY FOR THE DIII-D DIVERTOR [J].
BUCHENAUER, D ;
HSU, WL ;
SMITH, JP ;
HILL, DN .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10) :2873-2875
[3]   DESIGN AND OPERATION OF THE MULTIPULSE THOMSON SCATTERING DIAGNOSTIC ON DIII-D [J].
CARLSTROM, TN ;
CAMPBELL, GL ;
DEBOO, JC ;
EVANKO, R ;
EVANS, J ;
GREENFIELD, CM ;
HASKOVEC, J ;
HSIEH, CL ;
MCKEE, E ;
SNIDER, RT ;
STOCKDALE, R ;
TROST, PK ;
THOMAS, MP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10) :4901-4906
[4]  
CARLSTROM TN, 1996, P 11 INT C HIGH TEMP
[5]  
HILL DN, 1996, IN PRESS
[6]  
LEONARD A, 1996, COMMUNICATION
[7]  
NILSON DG, 1996, IN PRESS FUSION ENG
[8]   DIVERTOR HEAT-FLUX REDUCTION BY D(2) INJECTION IN DIII-D [J].
PETRIE, TW ;
BUCHENAUER, D ;
HILL, DN ;
KLEPPER, C ;
ALLEN, S ;
CAMPBELL, R ;
FUTCH, A ;
GROEBNER, RJ ;
LEONARD, A ;
LIPPMANN, S ;
MAHDAVI, MA ;
RENSINK, M ;
WEST, P .
JOURNAL OF NUCLEAR MATERIALS, 1992, 196 :848-853
[9]  
PETRIE TW, 1995, GAA21879
[10]  
PETRIE TW, 1991, 18TH P EUR C CONTR F, V3, P237