Sensitive determination of ammonia in exhaust gas of thermal power plant using gas permeation/flow injection system

被引:2
作者
Tsuboi, T
Hirano, Y
Shibata, Y
Motomizu, S
机构
[1] Chugoku Elect Power Co Inc, Tech Res Ctr, Higashihiroshima, Hiroshima 7390046, Japan
[2] Chuden Kankyo Technos Co Ltd, Higashihiroshima, Hiroshima 7390046, Japan
[3] Okayama Univ, Fac Sci, Dept Chem, Okayama 7008530, Japan
关键词
gas permeation system; ammonia; exhaust gas of a thermal power plant; FIA;
D O I
10.2116/bunsekikagaku.51.47
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection analysis coupled with a gas permeation unit for the sensitive determination of ammonia was investigated to improve the sensitivity and the rapidity of the determination of trace amounts of ammonia in exhaust gas. As gas sampling times are shortened, ammonium concentrations in absorption liquid(boric acid solution) will be lowered; the determination sensitivity of ammonia in the absorption liquid needs to be improved. Various experimental conditions, such as reagent solutions, sample sizes, reaction temperatures, flow rates of the reagent solutions and the length of gas permeation tube, were investigated and optimized. Of these, the reaction temperature and the length of gas permeation tube were found to greatly effect the sensitivity improvement for the determination of ammonia. The effect of the length of the microporous PTFE tube used for the gas permeation system was investigated by varying the length from 5 cm, to 50 cm. The results showed that is the 50 cm tube, the peak height was about 6 times higher than in the 10 cm tube, and the percentage of the permeation of ammonia was about 55% and 9% in the 50 cm and 10 cm tube, respectively. Under the optimized conditions, the limit of detection of ammonia was lowered down to on fifth of the previous system. The limit of detection corresponding to the standard deviation of the reagent blank of 3 was 4 mug l(-1) of NH4+. A calibration graph was linear from 10 mug l(-1) to 500 mug l(-1) of NH4+. The relative standard deviations for 50 mug l(-1) and 100 mug l(-1) of NH4+ were 4.5% and 2.3%, respectively. The proposed method was suitably applied to the determination of ammonia in the exhaust gas of the thermal power plant.
引用
收藏
页码:47 / 51
页数:5
相关论文
共 8 条
[1]  
[Anonymous], 1998, STANDARD METHODS EXA, DOI DOI 10.2-10.30
[2]  
Higuchi K, 1999, BUNSEKI KAGAKU, V48, P253
[3]  
*JIS, 1983, K0099 JIS
[4]  
KUWAKI T, 1987, BUNSEKI KAGAKU, V36, pT81
[5]   FULLY AUTOMATED-SYSTEM FOR THE CONTINUOUS MONITORING OF AMMONIUM ION IN FISH FARMING PLANT SEA-WATER BY FLOW-INJECTION ANALYSIS [J].
MURAKI, H ;
HIGUCHI, K ;
SASAKI, M ;
KORENAGA, T ;
TOEI, K .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :345-349
[6]  
TSUBOI T, 2000, J FLOW INJECTION ANA, V17, P77
[7]   DETERMINATION OF TOTAL AMMONIACAL NITROGEN IN WATER BY FLOW-INJECTION ANALYSIS AND A GAS-DIFFUSION MEMBRANE [J].
VANSON, M ;
SCHOTHORST, RC ;
DENBOEF, G .
ANALYTICA CHIMICA ACTA, 1983, 153 (OCT) :271-275
[8]  
2000, J FLOW INJECTION A S, V16, P45