Comparison of the efficacies of disinfectants to control microbial contamination in dental unit water systems in general dental practices across the European union

被引:59
作者
Schel, AJ
Marsh, PD
Bradshaw, DJ
Finney, M
Fulford, AR
Frandsen, E
Ostergaard, E
ten Cate, JM
Moorer, WR
Mavridou, A
Kamma, JJ
Mandilara, G
Stösser, L
Kneist, S
Araujo, R
Contreras, N
Goroncy-Bermes, P
O'Mullane, D
Burke, F
O'Reilly, P
Hourigan, G
O'Sullivan, M
Holman, R
Walker, JT
机构
[1] Hlth Protect Agcy, Ctr Emergency Preparedness & Response, Salisbury SP4 0JG, Wilts, England
[2] Univ Amsterdam, Acad Med Ctr, Dept Med Microbiol, NL-1105 AZ Amsterdam, Netherlands
关键词
D O I
10.1128/AEM.72.2.1380-1387.2006
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Water delivered by dental unit water systems (DUWS) in general dental practices can harbor high numbers of bacteria, including opportunistic pathogens. Biofilms on tubing within DUWS provide a reservoir for microorganisms and should be controlled. This study compared disinfection products for their ability to meet the American Dental Association's guideline of < 200 CFU (.) ml(-1) for DUWS water. Alpron, BioBlue, Dentosept, Oxygenal, Sanosil, Sterilex Ultra, and Ster4Spray were tested in DUWS (n = 134) in Denmark, Germany, Greece, Ireland, The Netherlands, Spain, and the United Kingdom. Weekly water samples were tested for total viable counts (TVCs) on yeast extract agar, and, where possible, the effects of products on established biofilm (TVCs) were measured. A 4- to 5-week baseline measurement period was followed by 6 to 8 weeks of disinfection (intermittent or continuous product application). DUWS water TVCs before disinfection ranged from 0 to 5.41 log CFU (.) ml(-1). Disinfectants achieved reductions in the median water TVC ranging from 0.69 (Ster4Spray) to 3.11 (Dentosept) log CFU (.) ml(-1), although occasional high values (up to 4.88 log CFU (.) ml(-1)) occurred with all products. Before treatment, 64% of all baseline samples exceeded American Dental Association guidelines, compared to only 17% following commencement of treatment; where tested, biofilm TVCs were reduced to below detectable levels. The antimicrobial efficacies of products varied (e.g., 91% of water samples from DUWS treated with Dentosept or Oxygenal met American Dental Association guidelines, compared to 60% of those treated with Ster4Spray). Overall, the continuously applied products performed better than those applied intermittently. The most effective products were Dentosept and Oxygenal, although Dentosept gave the most consistent and sustained antimicrobial effect over time.
引用
收藏
页码:1380 / 1387
页数:8
相关论文
共 56 条
[1]  
ADA, 1996, Journal of the American Dental Association, V127, P185
[2]  
[Anonymous], 1998, OFF J EUR UNION
[3]  
[Anonymous], 1994, MICROBIOLOGY WATER 1
[4]   LEGIONELLA CONTAMINATION OF DENTAL-UNIT WATERS [J].
ATLAS, RM ;
WILLIAMS, JF ;
HUNTINGTON, MK .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1995, 61 (04) :1208-1213
[5]   Cross infection control measures and the treatment of patients at risk of Creutzfeldt Jakob Disease in UK general dental practice [J].
Bagg, J ;
Sweeney, CP ;
Roy, KM ;
Sharp, T ;
Smith, A .
BRITISH DENTAL JOURNAL, 2001, 191 (02) :87-90
[6]  
Barbeau J, 2000, J Can Dent Assoc, V66, P539
[7]   Biofilms, infectious agents, and dental unit waterlines: a review [J].
Barbeau, J ;
Gauthier, C ;
Payment, P .
CANADIAN JOURNAL OF MICROBIOLOGY, 1998, 44 (11) :1019-1028
[8]   Microbial aerosols in general dental practice [J].
Bennett, AM ;
Fulford, MR ;
Walker, JT ;
Bradshaw, DJ ;
Martin, MV ;
Marsh, PD .
BRITISH DENTAL JOURNAL, 2000, 189 (12) :664-667
[9]  
BLAKE G. C., 1963, Brit. Dent. J., V115, P413
[10]   DETECTING LEGIONELLA-PNEUMOPHILA IN WATER-SYSTEMS - A COMPARISON OF VARIOUS DENTAL UNITS [J].
CHALLACOMBE, SJ ;
FERNANDES, LL .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1995, 126 (05) :603-608