Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria

被引:146
作者
Marten, K
Auer, F
Schmidt, S
Kohl, G
Rummeny, EJ
Engelke, C
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Radiol, D-81675 Munich, Germany
[2] Siemens Med Solut, Dept CTS W, D-91301 Forchheim, Germany
关键词
lung; nodule; lung neoplasms; computed tomography (CT); multi-detector row;
D O I
10.1007/s00330-005-0036-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to compare relative values of manual unidimensional measurements (MD) and automated volumetry (AV) for longitudinal treatment response assessment in patients with pulmonary metastases. Fifty consecutive patients with pulmonary metastases and repeat chest multidetector-row CT (median interval=2 months) were independently assessed by two radiologists for treatment response using Response Evaluation Criteria In Solid Tumours (RECIST). Statistics included relative measurement errors (RME), intra-/interobserver correlations, limits of agreement (95% LoA), and kappa. A total of 202 metastases (median volume=182.22 mm(3); range=3.16-5,195.13 mm(3)) were evaluated. RMEs were significantly higher for MD than for AV (intraobserver RME=2.34-3.73% and 0.15-0.22% for MD and AV respectively; P < 0.05. Interobserver RME=3.53-3.76% and 0.22-0.29% for MD and AV respectively; P < 0.05). Overall correlation was significantly better for AV than for MD (P < 0.05). Intraobserver 95% LoAs were -1.85 to 1.75 mm for MD and -11.28 to 9.84 mm(3) for AV. The interobserver 95% LoA were -1.46 to 1.92 mm for MD and -11.17 to 9.33 mm(3) for AV. There was total intra-/interobserver agreement on response using AV (kappa=1). MD intra- and interobserver agreements were 0.73-0.84 and 0.77-0.80 respectively. Of the 200 MD response ratings, 28 (14/50 patients) were discordant. Agreement using MD dropped significantly from total remission to progressive disease (P < 0.05). We therefore conclude that AV allows for better reproducibility of response evaluation in pulmonary metastases and should be preferred to MD in these patients.
引用
收藏
页码:781 / 790
页数:10
相关论文
共 26 条
[1]  
Altman DG, 1990, PRACTICAL STAT MED R
[2]  
BIGANZOLI L, 2002, EJC SUPPL, V36, pS90
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Interobserver and intraobserver variability in measurement of non-small-cell carcinoma lung lesions: Implications for assessment of tumor response [J].
Erasmus, JJ ;
Gladish, GW ;
Broemeling, L ;
Sabloff, BS ;
Truong, MT ;
Herbst, RS ;
Munden, RF .
JOURNAL OF CLINICAL ONCOLOGY, 2003, 21 (13) :2574-2582
[5]   Automatic segmentation of pulmonary nodules by using dynamic 3D cross-correlation for interactive CAD systems [J].
Fan, L ;
Qian, JZ ;
Odry, B ;
Shen, H ;
Naidich, D ;
Kohl, G ;
Klotz, E .
MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 :1362-1369
[6]  
Fleiss J. L., 1981, Statistical Methods for Rates and Proportions, V2nd
[7]   LARGE SAMPLE VARIANCE OF KAPPA IN THE CASE OF DIFFERENT SETS OF RATERS [J].
FLEISS, JL ;
NEE, JCM ;
LANDIS, JR .
PSYCHOLOGICAL BULLETIN, 1979, 86 (05) :974-977
[8]   Results of an independent oncology review board of pivotal clinical trials of gemcitabine in non-small cell lung cancer [J].
Gwyther, SJ ;
Aapro, MS ;
Hatty, SR ;
Postmus, PE ;
Smith, IE .
ANTI-CANCER DRUGS, 1999, 10 (08) :693-698
[9]   Small pulmonary nodules: Reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT [J].
Kostis, WJ ;
Yankelevitz, DF ;
Reeves, AP ;
Fluture, SC ;
Henschke, CI .
RADIOLOGY, 2004, 231 (02) :446-452
[10]   Computer-assisted detection of pulmonary nodules:: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings [J].
Marten, K ;
Grillhösl, A ;
Seyfarth, T ;
Obenauer, S ;
Rummeny, EJ ;
Engelke, C .
EUROPEAN RADIOLOGY, 2005, 15 (02) :203-212