Post-flashover fires for structural design

被引:51
作者
Feasey, R
Buchanan, A [1 ]
机构
[1] Opus Int Consultants, Auckland, New Zealand
[2] Univ Canterbury, Christchurch 1, New Zealand
关键词
D O I
10.1016/S0379-7112(01)00026-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
One of the major difficulties in designing structures to resist fires is the selection of post-flashover design fires. This paper proposes modifications to the parametric equation for post-flashover fires given in the Eurocode. The proposal is based on design fires obtained from the COMPF2 computer program, after calibration to results from realistic test fires using judicious characterisation of the fuel in the input data. The proposed new equation gives a much better fit to the real fire data than the existing Eurocode equation, which predicts temperatures lower than those measured in tests. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:83 / 105
页数:23
相关论文
共 25 条
[1]  
AKHIMIE N., 2017, Journal of Civil & Environmental Engineering, V4, P63
[2]  
[Anonymous], J FIRE PROTECTION EN
[3]  
[Anonymous], 1979, 991 NBS
[4]  
ARNAULT P, 1973, 373611F CECM CTR TEC
[5]  
ARNAULT P, 1974, 210203 CTR TECHN IND
[6]   A CLOSED-FORM APPROXIMATION FOR POST-FLASHOVER COMPARTMENT FIRE TEMPERATURES [J].
BABRAUSKAS, V .
FIRE SAFETY JOURNAL, 1981, 4 (01) :63-73
[7]   POST-FLASHOVER COMPARTMENT FIRES - APPLICATION OF A THEORETICAL-MODEL [J].
BABRAUSKAS, V ;
WILLIAMSON, RB .
FIRE AND MATERIALS, 1979, 3 (01) :1-7
[8]   POST-FLASHOVER COMPARTMENT FIRES - BASIS OF A THEORETICAL-MODEL [J].
BABRAUSKAS, V ;
WILLIAMSON, RB .
FIRE AND MATERIALS, 1978, 2 (02) :39-53
[9]  
CLIFTON G, 1996, R483 HERA
[10]  
Drysdale D., 1998, An introduction to fire Dynamics