Intraaortic Protection From Embolization in Patients Undergoing Transaortic Transcatheter Aortic Valve Implantation

被引:74
作者
Wendt, Daniel
Kleinbongard, Petra
Knipp, Stephan
Al-Rashid, Fadi
Gedik, Nilguen
El Chilali, Karim
Schweter, Sebastian
Schlamann, Marc
Kahlert, Philipp
Neuhaeuser, Markus
Forsting, Michael
Erbel, Raimund
Heusch, Gerd
Jakob, Heinz
Thielmann, Matthias
机构
[1] Univ Hosp Essen, West German Heart & Vasc Ctr Essen, Dept Thorac & Cardiovasc Surg, Inst Pathophysiol,Dept Cardiol, Essen, Germany
[2] Univ Hosp Essen, Inst Diagnost & Intervent Radiol & Neuroradiol, Essen, Germany
[3] Koblenz Univ Appl Sci, Dept Math & Technol, Remagen, Germany
关键词
REPLACEMENT;
D O I
10.1016/j.athoracsur.2015.03.119
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Purpose. Transcatheter aortic valve implantation (TAVI) results in the dislodgement of debris with risk of cerebral lesions or stroke. The EMBOL-X protection device (Edwards Lifesciences, Irvine, CA) is positioned within the ascending aorta to capture such debris. Description. Between July 2012 and April 2014 we randomly assigned 30 high-risk patients to undergo transaortic TAVI with the SAPIEN XT prosthesis (Edwards Lifesciences) combined with either the EMBOL-X device (group-1, n = 14) or without (group-2, n = 16). Periprocedural cerebral lesions were assessed by diffusion-weighted magnetic resonance imaging (DW-MRI) at baseline and within 7 days post-procedurally. Evaluation. New foci of restricted diffusion on cerebral DW-MRI were found in 69% in group-2 and 50% in group-1. Lesion size was smaller in patients treated with the EMBOL-X device than in those without (88 +/- 60 vs 168 +/- 217 mm(3), p = 0.27, t [1.2, degrees of freedom = 10). Transaortic TAVI patients treated with the EMBOL-X device had significantly smaller lesion volumes in the supply region of the middle cerebral artery (33 +/- 29 vs 76 +/- 67 mm(3), p = 0.04). There were no neurologic events after transaortic TAVI. Conclusions. The intraaortic protection device seems to reduce both the incidence and the volume of new cerebral lesions (C) 2015 by The Society of Thoracic Surgeons
引用
收藏
页码:686 / 691
页数:6
相关论文
共 7 条
[1]
Transaortic Transcatheter Aortic Valve Implantation: Step-by-Step Guide [J].
Bapat, Vinnie ;
Attia, Rizwan .
SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2012, 24 (03) :206-211
[2]
Embol-X Intraaortic Filter and Transaortic Approach for Improved Cerebral Protection in Transcatheter Aortic Valve Implantation [J].
Etienne, Pierre-Yves ;
Papadatos, Spiridon ;
Pieters, Denis ;
El Khoury, Elie ;
Alexis, Frederic ;
Price, Joel ;
Glineur, David .
ANNALS OF THORACIC SURGERY, 2011, 92 (05) :E95-E96
[3]
Cerebral Embolization During Transcatheter Aortic Valve Implantation A Transcranial Doppler Study [J].
Kahlert, Philipp ;
Al-Rashid, Fadi ;
Doettger, Philipp ;
Mori, Kathrine ;
Plicht, Bjoern ;
Wendt, Daniel ;
Bergmann, Lars ;
Kottenberg, Eva ;
Schlamann, Marc ;
Mummel, Petra ;
Holle, Dagny ;
Thielmann, Matthias ;
Jakob, Heinz G. ;
Konorza, Thomas ;
Heusch, Gerd ;
Erbel, Raimund ;
Eggebrecht, Holger .
CIRCULATION, 2012, 126 (10) :1245-+
[4]
Silent and Apparent Cerebral Ischemia After Percutaneous Transfemoral Aortic Valve Implantation A Diffusion-Weighted Magnetic Resonance Imaging Study [J].
Kahlert, Philipp ;
Knipp, Stephan C. ;
Schlamann, Marc ;
Thielmann, Matthias ;
Al-Rashid, Fadi ;
Weber, Marcel ;
Johansson, Uw ;
Wendt, Daniel ;
Jakob, Heinz G. ;
Forsting, Michael ;
Sack, Stefan ;
Erbel, Raimund ;
Eggebrecht, Holger .
CIRCULATION, 2010, 121 (07) :870-878
[5]
Feasibility and Exploratory Efficacy Evaluation of the Embrella Embolic Deflector System for the Prevention of Cerebral Emboli in Patients Undergoing Transcatheter Aortic Valve Replacement The PROTAVI-C Pilot Study [J].
Rodes-Cabau, Josep ;
Kahlert, Philip ;
Neumann, Franz-Josef ;
Schymik, Gerhard ;
Webb, John G. ;
Amarenco, Pierre ;
Brott, Thomas ;
Garami, Zsolt ;
Gerosa, Gino ;
Lefevre, Thierry ;
Plicht, Bjoern ;
Pocock, Stuart J. ;
Schlamann, Marc ;
Thomas, Martyn ;
Diamond, Beverly ;
Merioua, Ihsen ;
Beyersdorf, Friedhelm ;
Vahanian, Alec .
JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (10) :1146-1155
[6]
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients [J].
Smith, Craig R. ;
Leon, Martin B. ;
Mack, Michael J. ;
Miller, Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Williams, Mathew ;
Dewey, Todd ;
Kapadia, Samir ;
Babaliaros, Vasilis ;
Thourani, Vinod H. ;
Corso, Paul ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (23) :2187-2198
[7]
Reduction of neurologic complications by intra-aortic filtration in patients undergoing combined intracardiac and CABG procedures [J].
Wimmer-Greinecker, G .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 23 (02) :159-163