Experimental evaluation of ride-through capabilities for a matrix converter under short power interruptions

被引:39
作者
Klumpner, C [1 ]
Blaabjerg, F [1 ]
机构
[1] Aalborg Univ, Inst Energy Technol, DK-9220 Aalborg, Denmark
关键词
AC-AC power conversion; flying start; ride-through operation; variable-speed drives;
D O I
10.1109/41.993264
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 [计算机科学与技术];
摘要
The matrix converters, which are direct power electronic converters, are able to provide important benefits such as bidirectional power flow, sinusoidal input currents with adjustable displacement angle, and a great potential for size reduction. Still, two major disadvantages exist: a lower than unity voltage transfer ratio and high sensitivity to power grid disturbances. Many solutions to provide continuous operation of adjustable speed drives (ASDs) during power grid disturbances have been proposed, but they are all applied to dc-link ASD. In this paper, a new solution to provide limited ride-through operation is presented with a matrix converter using a scalar controlled induction motor for a duration of hundreds of milliseconds, without any hardware modification. During the ride-through operation, the drive is not able to develop torque or to control the motor flux. By recovering the necessary power to feed the control hardware of the matrix converter, it is able to keep the ASD operating. When normal grid conditions are reestablished, the matrix converter is able to accelerate the motor from nonzero speed and flux by initializing the modulator with the estimated frequency and the initial angle of the reference output voltage vector. The maximum duration of the ride-through operation depends on the initial motor flux, speed level, rotor time constant, load torque, and inertia. This method is verified on a laboratory setup with a matrix converter.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 31 条
[1]
*ABB IND OY, ACS 600 SINGL DRIV F
[2]
Blaabjerg F, 2000, PROCEEDINGS OF THE 2000 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOL 1 AND 2, P465, DOI 10.1109/ISIE.2000.930342
[3]
SAFE CONTROL OF 4-QUADRANT SWITCHES [J].
BURANY, N .
CONFERENCE RECORD OF THE 1989 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, PTS 1-2, 1989, :1190-1194
[4]
CHATTOPADHYAY S, 1993, P IND COMM POW SYST, P78
[5]
COLLINS ER, 1997, P IEEE ANN TEXT FIB, P1
[6]
CORLEY M, 1999, P 30 ANN IEEE POW EL, V1, P26
[7]
DAVID A, 1993, IEE CONF PUBL, P139
[8]
DAVID A, 1993, IEE CONF PUBL, P570
[9]
DRINKWATER DL, 1991, Patent No. 4818891
[10]
Effect of voltage sags on adjustable-speed drives:: A critical evaluation and an approach to improve performance [J].
Durán-Gómez, JL ;
Enjeti, PN ;
Woo, BO .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (06) :1440-1449