Pulse multiplication in AC-DC converters for harmonic mitigation in vector-controlled induction motor drives

被引:41
作者
Singh, Bhim [1 ]
Bhuvaneswari, G. [1 ]
Garg, Vipin [1 ]
Gairola, Sanjay [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, New Delhi 110016, India
关键词
Au totransformer; multipulse ac-dc converter; pulse multiplication; vector controlled induction motor drives (VCIMD);
D O I
10.1109/TEC.2006.874217
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 [动力工程及工程热物理]; 0820 [石油与天然气工程];
摘要
In this paper, an autotransformer with reduced kilovoltampere rating for 24-pulse ac-dc converter fed vector controlled induction motor drives (VCIMDs) is presented for harmonic current reduction. The 24-pulse operation is achieved using dc ripple reinjection technique in 12-pulse ac-dc converters. The proposed novel harmonic mitigator is found capable of suppressing up to 21st harmonic in the supply current. The procedure for the design of autotransformer for proposed ac-dc converter is presented to show the flexibility in the design for making it a cost-effective replacement suitable for retrofit applications, where presently a 6-pulse diode bridge rectifier is used. The effect of load variation on VCIMD is also studied to demonstrate the effectiveness of the proposed ac-dc converter. A set of power quality indices on input ac mains and on dc bus for a VCIMD fed from other 24-pulse ac-dc converters are also given to compare their performance. The laboratory prototypes of proposed autotransformers based 12-pulse and 24-pulse ac-dc converters are developed and test results are presented to validate the developed design procedure and the simulation models of these ac-dc converters under varying loads.
引用
收藏
页码:342 / 352
页数:11
相关论文
共 12 条
[1]
[Anonymous], 5191992 IEEE
[2]
Polyphase transformer arrangements with reduced kVA capacities for harmonic current reduction in rectifier-type utility interface [J].
Choi, S ;
Enjeti, PN ;
Pitel, IJ .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1996, 11 (05) :680-690
[3]
Choi S, 1997, IEEE T IND APPL, V33, P531, DOI 10.1109/28.568020
[4]
Hammond Peter, 1997, U.S. Patent, Patent No. [5,619,407, 5619407]
[5]
HANSEN S, 2001, P 2001 IEEE APEC1 C, V2, P806
[6]
Kamath GR, 2001, IEEE IND ELEC, P1344, DOI 10.1109/IECON.2001.975977
[7]
NEW METHOD FOR REDUCING HARMONICS INVOLVED IN INPUT AND OUTPUT OF RECTIFIER WITH INTERPHASE TRANSFORMER [J].
MIYAIRI, S ;
IIDA, S ;
NAKATA, K ;
MASUKAWA, S .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1986, 22 (05) :790-797
[8]
Paice D. A, 1989, U. S. Patent, Patent No. [4,876,634, 4876634]
[9]
Paice D. A., 2000, U.S.Patent, Patent No. 6101113
[10]
Paice D.A., 1996, Power Electronic Converter Harmonics: Multipulse Methods for Clean Power