Laser Doppler velocimetry uses the frequency shift produced by the Doppler effect to measure velocity. It can be used to monitor blood flow or other tissue movement in the body. Laser speckle is a random interference effect that gives a grainy appearance to objects illuminated by laser light. If the object consists of individual moving scatterers (such as blood cells), the speckle pattern fluctuates. These fluctuations provide information about the velocity distribution of the scatterers. It can be shown that the speckle and Doppler approaches are different ways of looking at the same phenomenon. Both these techniques measure at a single point. If a map of the velocity distribution is required, some form of scanning must be introduced. This has been done for both time-varying speckle and laser Doppler. However, with the speckle technique it is also possible to devise a full-field technique that gives an instantaneous map of velocities in real time, This review article presents the theory and practice of these techniques using a tutorial approach and compares the relative merits of the scanning and full-field approaches to velocity map imaging. The article concludes with a review of reported applications of these techniques to blood perfusion mapping and imaging.
引用
收藏
页码:R35 / R66
页数:32
相关论文
共 130 条
  • [1] Abbiss J. B., 1974, Optics and Laser Technology, V6, P249, DOI 10.1016/0030-3992(74)90006-1
  • [2] Coherent optical techniques for diagnostics of retinal blood flow
    Aizu, Y
    Asakura, T
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) : 61 - 75
  • [3] MEASUREMENTS OF FLOW VELOCITY IN A MICROSCOPIC REGION USING DYNAMIC LASER SPECKLES BASED ON THE PHOTON-CORRELATION
    AIZU, Y
    AMBAR, H
    YAMAMOTO, T
    ASAKURA, T
    [J]. OPTICS COMMUNICATIONS, 1989, 72 (05) : 269 - 273
  • [4] EVALUATION OF FLOW VOLUME IN A CAPILLARY USING DYNAMIC LASER SPECKLES BASED ON THE PHOTON-CORRELATION
    AIZU, Y
    ASAKURA, T
    OGINO, K
    SUGITA, T
    [J]. OPTICS COMMUNICATIONS, 1990, 80 (01) : 1 - 6
  • [5] BIO-SPECKLE PHENOMENA AND THEIR APPLICATION TO THE EVALUATION OF BLOOD-FLOW
    AIZU, Y
    ASAKURA, T
    [J]. OPTICS AND LASER TECHNOLOGY, 1991, 23 (04) : 205 - 219
  • [6] EVALUATION OF BLOOD-FLOW AT OCULAR FUNDUS BY USING LASER SPECKLE
    AIZU, Y
    OGINO, K
    SUGITA, T
    YAMAMOTO, T
    TAKAI, N
    ASAKURA, T
    [J]. APPLIED OPTICS, 1992, 31 (16): : 3020 - 3029
  • [7] Aizu Y, 1990, J CLIN LASER MED SUR, V8, P35
  • [8] Laser Doppler imaging of activation-flow coupling in the rat somatosensory cortex
    Ances, BM
    Greenberg, JH
    Detre, JA
    [J]. NEUROIMAGE, 1999, 10 (06) : 716 - 723
  • [9] [Anonymous], 1977, LASER SYSTEMS FLOW M
  • [10] COMPARATIVE-STUDY OF 2 LASER DOPPLER BLOOD FLOWMETERS
    BARNETT, NJ
    DOUGHERTY, G
    PETTINGER, SJ
    [J]. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1990, 14 (06) : 243 - 249