Microirrigation lateral design using lateral discharge equation

被引:18
作者
Jain, SK [1 ]
Singh, KK
Singh, RP
机构
[1] Rajendra Agr Univ, Coll Agr Engn, Bihar 848125, Pusa, India
[2] Govind Ballabh Pant Univ Agr & Technol, Dept Irrigat & Drainage Engn, Pantnagar 263145, Uttar Pradesh, India
关键词
irrigation; laterals; flow rates; design; water discharge;
D O I
10.1061/(ASCE)0733-9437(2002)128:2(125)
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
A simple and accurate method is developed for designing single, paired, and tapered microirrigation laterals. The hydraulics of the lateral is evaluated using a lateral discharge equation approach. A simple power equation is used to express the relationship between the inlet flow rate and inlet pressure head of the lateral. Keeping the flow variation within the specified limit, a procedure for designing the length of the tapered section is developed. The lateral is designed using a step-by-step method. The length of the tapered section is determined by the golden section search method.
引用
收藏
页码:125 / 128
页数:4
相关论文
共 12 条
[1]   ANALYSIS AND DESIGN OF TRICKLE-IRRIGATION LATERALS [J].
HATHOOT, HM ;
ALAMOUD, AI ;
MOHAMMAD, FS .
JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 1993, 119 (05) :756-767
[2]  
Howell T. A., 1974, Journal of the Irrigation and Drainage Division, Proceedings of the American Society of Civil Engineers, V100, P443
[3]  
Kang Y, 1996, T ASAE, V39, P1681, DOI 10.13031/2013.27685
[4]  
KANG Y, 1995, T ASAE, V38, P1377, DOI 10.13031/2013.27961
[5]  
Kang Y, 1996, T ASAE, V39, P921, DOI 10.13031/2013.27577
[6]  
KANG Y, 1995, P 5 INT MICR C ST JO, P84
[7]   Analysis and design of microirrigation laterals [J].
Kang, YH ;
Nishiyama, S .
JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING-ASCE, 1996, 122 (02) :75-82
[8]  
Karmeli D., 1985, IRRIGATION SYSTEMS D
[9]  
KELLER J, 1974, T ASAE, V17, P678, DOI 10.13031/2013.36936
[10]  
Perold R. P., 1977, Journal of the Irrigation and Drainage Division, American Society of Civil Engineers, V103, P179