Integrated RF coil with stabilization for fMRI human cortex

被引:19
作者
Fitzsimmons, JR [1 ]
Scott, JD [1 ]
Peterson, DM [1 ]
Wolverton, BL [1 ]
Webster, CS [1 ]
Lang, PJ [1 ]
机构
[1] UNIV FLORIDA,DEPT CLIN & HLTH PSYCHOL,GAINESVILLE,FL 32610
关键词
fMRI; phased array; multichannel receiver; RF coils;
D O I
10.1002/mrm.1910380104
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Functional brain imaging of the human cortex is limited by poor contrast to noise ratio (CNR) and image degradation due to subject motion during the acquisition period. The work described here combines the use of closely coupled phased array receiver coils with a stabilization system to address these needs, Several phased array designs are evaluated and compared with the conventional ''birdcage'' design. Coil performance is reported in terms of relative SNR and fMRI results, Relative improvements of up to 360% are obtained for the occipital region and 180% in the temporal region. More modest gains of 10-30% were obtained for a ''dome''-shaped birdcage volume coil covering the entire cortex.
引用
收藏
页码:15 / 18
页数:4
相关论文
共 12 条
  • [1] FUNCTIONAL MAPPING OF THE HUMAN VISUAL-CORTEX BY MAGNETIC-RESONANCE-IMAGING
    BELLIVEAU, JW
    KENNEDY, DN
    MCKINSTRY, RC
    BUCHBINDER, BR
    WEISSKOFF, RM
    COHEN, MS
    VEVEA, JM
    BRADY, TJ
    ROSEN, BR
    [J]. SCIENCE, 1991, 254 (5032) : 716 - 719
  • [2] ELIMINATION OF COUPLING BETWEEN CYLINDRICAL TRANSMIT COILS AND SURFACE-RECEIVE COILS FOR INVIVO NMR
    BENDALL, MR
    CONNELLY, A
    MCKENDRY, JM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (01) : 157 - 163
  • [3] FITZSIMMONS JR, 1995, P SMR 3 ANN M, P976
  • [4] FOO TK, 1990, MAGNET RESON MED, V21, P165
  • [5] PROJECTION RECONSTRUCTION TECHNIQUES FOR REDUCTION OF MOTION EFFECTS IN MRI
    GLOVER, GH
    PAULY, JM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) : 275 - 289
  • [6] GLOVER GH, 1993, 12TH P SMRM ANN M NE, P197
  • [7] AN EFFICIENT, HIGHLY HOMOGENEOUS RADIOFREQUENCY COIL FOR WHOLE-BODY NMR IMAGING AT 1.5-T
    HAYES, CE
    EDELSTEIN, WA
    SCHENCK, JF
    MUELLER, OM
    EASH, M
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (03) : 622 - 628
  • [8] DYNAMIC MAGNETIC-RESONANCE-IMAGING OF HUMAN BRAIN ACTIVITY DURING PRIMARY SENSORY STIMULATION
    KWONG, KK
    BELLIVEAU, JW
    CHESLER, DA
    GOLDBERG, IE
    WEISSKOFF, RM
    PONCELET, BP
    KENNEDY, DN
    HOPPEL, BE
    COHEN, MS
    TURNER, R
    CHENG, HM
    BRADY, TJ
    ROSEN, BR
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (12) : 5675 - 5679
  • [9] SPIRAL K-SPACE MR-IMAGING OF CORTICAL ACTIVATION
    NOLL, DC
    COHEN, JD
    MEYER, CH
    SCHNEIDER, W
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (01): : 49 - 56
  • [10] THE NMR PHASED-ARRAY
    ROEMER, PB
    EDELSTEIN, WA
    HAYES, CE
    SOUZA, SP
    MUELLER, OM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) : 192 - 225