A gas chromatographic-based headspace biochemical oxygen demand test

被引:17
作者
Logan, BE
Patnaik, R
机构
[1] Environmental Engineering Program, Dept. of Chem. and Environ. Eng.
[2] Dept. of Chem. and Environ. Eng., Bldg. #72, University of Arizona, Tucson
关键词
analysis; biochemical oxygen demand; effluents; gas chromatography; headspace;
D O I
10.2175/106143097X125362
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The 5-day biochemical oxygen demand (BOD5) test is an established tool for measuring the concentration of biodegradable organic matter in wastewater effluents. Unfortunately, the BOD test is time consuming, labor intensive, and, due to the dilution of the wastewater, takes a relatively long time to complete. A few years ago a headspace BOD (HBOD) test was developed that avoided the need to dilute wastewater samples. A disadvantage of the original HBOD test was that the sample had to be transferred from the HBOD tube to another vessel for a dissolved oxygen measurement. This study demonstrates that it is possible to conduct HBOD tests using a gas chromatograph to measure oxygen utilization in the sealed tube and that a 3-day HBOD provides a reliable estimate of the BOD5. The HBOD3 values measured for primary and secondary clarifier effluents from an activated sludge plant were 114 and 23 mg/L; BOD5 measurements were 116 and 24 mg/L. Changes in headspace volumes did not significantly change the HBODs. Secondary settled wastewater had a HBOD5 of 83 +/- 3 mg/L (mean +/- SD) for headspace volumes of 10-20 mL (36-71%) in a 28-mL tube. The HBOD5 was also constant (84 +/- 6 mg/L) when samples were diluted 20-60% using BOD dilution water at a fixed headspace volume of 8 mL in HBOD tubes. Nitrification increased the HBOD of nondiluted wastewaters after 4 days, although nitrification appeared to be sufficiently inhibited using a standard nitrification inhibitor. A calibration test for the HBOD was developed using a 300-mg/L glucose and glutamic acid (GGA, 50% each) solution and secondary clarifier wastewater that provided HBOD3 values similar to those obtained in the analogous BOD3 test. It is argued that the simpler procedures, added precision of CC-based protocols, and more rapid exertion of oxygen demand make the HBOD test superior to the conventional BOD test.
引用
收藏
页码:206 / 214
页数:9
相关论文
共 11 条
[1]  
*AM PUBL HLTH ASS, 1995, STAND METH EX WAT WA
[2]  
BUSCH AW, 1958, SEWAGE IND WASTES, V30, P1336
[3]  
HILL G, 1995, P 17 ANN EPA C AN PO
[4]  
HISER LL, 1964, J WATER POLLUT CON F, V36, P505
[5]   THE HBOD TEST - A NEW METHOD FOR DETERMINING BIOCHEMICAL OXYGEN-DEMAND [J].
LOGAN, BE ;
WAGENSELLER, GA .
WATER ENVIRONMENT RESEARCH, 1993, 65 (07) :862-868
[6]  
MULLIS MK, 1971, J WATER POLLUT CON F, V43, P209
[7]  
OBRIEN WJ, 1962, B ENG EXPT STATION, V20
[8]  
PATNAIK R, 1996, THESIS U ARIZONA TUC
[9]  
Rozich A. F., 1992, DESIGN OPERATION ACT
[10]  
YOUNG JC, 1976, WATER RES, V10, P1041