Flow injection Fourier transform infrared determination of nicotine in tobacco

被引:19
作者
Garrigues, JM [1 ]
Pérez-Ponce, A [1 ]
Garrigues, S [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Burjassot, Valencia, Spain
关键词
D O I
10.1039/a809590f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully automated procedure is proposed for the Fourier transform infrared (FTIR) determination of nicotine in tobacco. The method is based on the on-line extraction of nicotine with CHCl3. Samples, weighed inside empty extraction cartridges, were humidified with NH3 and the cartridges were installed in a flow manifold in which they were extracted with 2 ml CHCl3 for 2 min, then 400 mu l of the extract were introduced into a micro-flow cell using a carrier of CHCl3 and the DR spectrum was registered continuously. The absorbance, in the wavenumber range 1334-1300 cm(-1), was measured, obtaining a peak as a function of time. The area of this peak was interpolated on a calibration line established from Standard solutions of nicotine in chloroform treated in the same way as samples. The method provided a limit of detection of 0.1 mg ml(-1) nicotine, an RSD lower than 2% and a sampling frequency of the whole procedure of 6 h(-1). Results obtained for natural samples of cut tobacco and cigar compared well with those obtained by a batch FTIR procedure, involving an off-line extraction with a total time of 16 min. However, for yellow tobacco cigarette, an on-line extraction time of 10 min was required to obtain a good recovery of nicotine.
引用
收藏
页码:783 / 786
页数:4
相关论文
共 12 条
[1]  
Collins P., 1969, TOBACCO SCI, V13, P79
[2]   Flow injection Fourier transform infrared determination of caffeine in soft drinks [J].
Daghbouche, Y ;
Garrigues, S ;
Vidal, MT ;
delaGuardia, M .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1086-1091
[3]  
DAGHBOUCHE Y, 1995, ANAL CHIM ACTA, V308, P462
[4]  
DAVIS RE, 1976, TOBACCO SCI, V20, P146
[5]   AUTOMATED STUDIES OF TOBACCO USING FLOW-INJECTION ANALYSIS (FIA) [J].
FINSTER, P ;
HOLLWEG, J ;
KAUSCH, E ;
BURMESTER, U .
BEITRAGE ZUR TABAKFORSCHUNG INTERNATIONAL, 1988, 14 (02) :105-118
[6]   Fourier-transform infrared determination of nicotine in tobacco samples by transmittance measurements after leaching with CHCl3 [J].
Garrigues, JM ;
Pérez-Ponce, A ;
Garrigues, S ;
de la Guardia, M .
ANALYTICA CHIMICA ACTA, 1998, 373 (01) :63-71
[7]   ONLINE PRECONCENTRATION AND FLOW-ANALYSIS FOURIER-TRANSFORM INFRARED DETERMINATION OF CARBARYL [J].
GARRIGUES, S ;
VIDAL, MT ;
GALLIGNANI, M ;
DELAGUARDIA, M .
ANALYST, 1994, 119 (04) :659-664
[8]  
HARVEY W R, 1969, Tobacco (New York), V13, P13
[9]  
HARVEY WR, 1981, TOBACCO SCI, V25, P131
[10]   AN AUTOMATED PROCEDURE FOR THE DETERMINATION OF TOTAL ALKALOIDS IN CIGARETTE-SMOKE USING ONLINE CYANOGEN CHLORIDE GENERATION FROM LOW HAZARD STARTING MATERIALS [J].
LIDZEY, RG ;
SAVAGE, GP .
BEITRAGE ZUR TABAKFORSCHUNG INTERNATIONAL, 1986, 13 (03) :151-155