Enzymatically-generated fluorescent detection in micro-channels with internal magnetic mixing for the development of parallel microfluidic ELISA

被引:96
作者
Herrmann, M
Veres, T
Tabrizian, M [1 ]
机构
[1] McGill Univ, Dept Biomed Engn, Montreal, PQ H3A 2B4, Canada
[2] Natl Res Council Canada, Inst Ind Mat, Boucherville, PQ J4B 6Y4, Canada
关键词
D O I
10.1039/b516031f
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The Enzyme-Linked Immuno-Sorbent Assay, or ELISA, is commonly utilized to quantify small concentrations of specific proteins for a large variety of purposes, ranging from medical diagnosis to environmental analysis and food safety. However, this technique requires large volumes of costly reagents and long incubation periods. The use of microfluidics permits one to specifically address these drawbacks by decreasing both the volume and the distance of diffusion inside the micro-channels. Existing microfluidic systems are limited by the necessary control of extremely low flow rates to provide sufficient time for the molecules to interact with each other by diffusion only. In this paper, we describe a new microfluidic design for the realization of parallel ELISA in stop-flow conditions. Magnetic beads were used both as a solid phase to support the formation of the reactive immune complex and to achieve a magnetic mixing inside the channels. In order to test the detection procedure, the formation of the immune complex was performed off-chip before the reactive beads were injected into the reaction chamber. Anti-streptavidin antibodies were quantified with low picomolar sensitivity (0.1 - 6.7 pM), a linear range of 2 orders of magnitude and good reproducibility. This work represents the first step toward a new platform for simple, highly effective and parallel microfluidic ELISA.
引用
收藏
页码:555 / 560
页数:6
相关论文
共 38 条
  • [1] Micromosaic immunoassays
    Bernard, A
    Michel, B
    Delamarche, E
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (01) : 8 - 12
  • [2] Real-time QCM-D immunoassay through oriented antibody immobilization using cross-linked hydrogel biointerfaces
    Carrigan, SD
    Scott, G
    Tabrizian, M
    [J]. LANGMUIR, 2005, 21 (13) : 5966 - 5973
  • [3] Toward resolving the challenges of sepsis diagnosis
    Carrigan, SD
    Scott, G
    Tabrizian, M
    [J]. CLINICAL CHEMISTRY, 2004, 50 (08) : 1301 - 1314
  • [4] High-sensitivity miniaturized immunoassays for tumor necrosis factor a using microfluidic systems
    Cesaro-Tadic, S
    Dernick, G
    Juncker, D
    Buurman, G
    Kropshofer, H
    Michel, B
    Fattinger, C
    Delamarche, E
    [J]. LAB ON A CHIP, 2004, 4 (06) : 563 - 569
  • [5] An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications
    Chabinyc, ML
    Chiu, DT
    McDonald, JC
    Stroock, AD
    Christian, JF
    Karger, AM
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (18) : 4491 - 4498
  • [6] An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities
    Choi, JW
    Oh, KW
    Thomas, JH
    Heineman, WR
    Halsall, HB
    Nevin, JH
    Helmicki, AJ
    Henderson, HT
    Ahn, CH
    [J]. LAB ON A CHIP, 2002, 2 (01) : 27 - 30
  • [7] Improving agglutination tests by working in microfluidic channels
    Degré, G
    Brunet, E
    Dodge, A
    Tabeling, P
    [J]. LAB ON A CHIP, 2005, 5 (06): : 691 - 694
  • [8] Fabrication of magnetic microfiltration systems using soft lithography
    Deng, T
    Prentiss, M
    Whitesides, GM
    [J]. APPLIED PHYSICS LETTERS, 2002, 80 (03) : 461 - 463
  • [9] Manipulation of magnetic microbeads in suspension using micromagnetic systems fabricated with soft lithography
    Deng, T
    Whitesides, GM
    Radhakrishnan, M
    Zabow, G
    Prentiss, M
    [J]. APPLIED PHYSICS LETTERS, 2001, 78 (12) : 1775 - 1777
  • [10] Rapid prototyping of microfluidic systems in poly(dimethylsiloxane)
    Duffy, DC
    McDonald, JC
    Schueller, OJA
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (23) : 4974 - 4984