Analysis of reject x-ray films as quality assurance element in diagnostic radiology

被引:12
作者
Lewentat, G [1 ]
Bohndorf, K [1 ]
机构
[1] ZENT KLINIKUM,KLIN DIAGNOST RADIOL & NEURORADIOL,D-86156 AUGSBURG,GERMANY
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1997年 / 166卷 / 05期
关键词
quality assurance; reject film; images; radiography;
D O I
10.1055/s-2007-1015445
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Analysis of reject films from a large radiological department under the following aspects: How big is the waste of films? Where are the sources of error? What are the possible means of quality assurance? Material and method: During a total period of 9 months, separated into three quarters, 14570 reject films were analysed and assigned to 4 categories (''positioning'', ''exposure'', ''reject films due to patients'' and ''others''). In addition they were classified according to the respective parts of the body. The influence of a ''study effect'' was quantified by the analysis before and after information of staff. Results: The reject film rate in relation to all performed x-rays, was 9.0-13.2% of all the films taken during that period; of these, the failure rate (x-rays useless for diagnosis because of their bad quality) was between 54.2 and 57.5%. In this category, the main sources of error were positioning (55%) and exposure (34%). Surprisingly, the technical film waste amounted to 42.5-45.8% (not developed or preexposed films, x-rays of phantoms etc.). Conclusion: Wasted films due to errors occurring during taking, as well as technical film waste, are unavoidable. Their proportion in relation to the total number of films should not exceed 8%. The main approach to reducing cost must be to cut down technical film waste.
引用
收藏
页码:376 / 381
页数:6
相关论文
共 12 条
[1]   REJECT ANALYSIS - A PILOT PROGRAM FOR IMAGE QUALITY MANAGEMENT [J].
ARVANITIS, TN ;
PARIZEL, PM ;
DEGRYSE, HR ;
DESCHEPPER, AMA .
EUROPEAN JOURNAL OF RADIOLOGY, 1991, 12 (03) :171-176
[2]  
Bourne D, 1969, Radiography, V35, P257
[3]  
Brandt G A, 1987, Radiol Diagn (Berl), V28, P271
[4]  
GADEHOLT G, 1989, EUR J RADIOL, V9, P137
[5]  
Gothlin J H, 1986, Radiol Diagn (Berl), V27, P45
[6]  
Henshaw E T, 1990, Qual Assur Health Care, V2, P213
[7]   INCIDENCE AND CAUSES OF REPEATED RADIOGRAPHIC EXAMINATIONS IN A COMMUNITY HOSPITAL [J].
MAZZAFERRO, RJ ;
BALTER, S ;
JANOWER, ML .
RADIOLOGY, 1974, 112 (01) :71-72
[8]   SPOILT FILMS IN X-RAY DEPARTMENTS [J].
MCKINLAY, A ;
MCCAULEY, B .
BRITISH JOURNAL OF RADIOLOGY, 1977, 50 (591) :233-234
[9]  
ROBERTS DP, 1988, RADIOGRAPHIC IMAGING, P209
[10]  
STARGARDT A, 1983, MOD RONTGENPHOTOGR, V2, P26