A simplified broadband coupling approach applied to chemically robust sol-gel, planar integrated optical waveguides

被引:39
作者
Bradshaw, JT
Mendes, SB
Saavedra, SS [1 ]
机构
[1] Univ Arizona, Dept Chem, Tucson, AZ 85721 USA
[2] Univ Arizona, Ctr Opt Sci, Tucson, AZ 85721 USA
关键词
D O I
10.1021/ac011112r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new generation waveguide spectrometer with broadband coupling capabilities has been developed. As opposed to previous devices, this attenuated total reflection (ATR) spectrometer is much simpler in design, is more chemically robust, and transmits light down to at least 400 mn. The attenuated total reflection element consists of a single-mode, planar integrated optical waveguide fabricated by dip-coating a similar to300 mn thick, sol-gel composite layer on a glass substrate. A commercially available prism is used as the incoupler with an integral holographic diffraction grating acting as the dispersive outcoupling element. The transmission of narrow band-pass filters was used to compare the response of the waveguide spectrometer to that of a conventional transmission instrument. Spectral resolution was assessed by measuring the fwhm of various laser lines, which were found to range from 0.5 to 1.3 mn. The measured limits of detection for the waveguide spectrometer from 400 to 600 nm are 8.0 and 10.1 milliabsorbance units for TE and TM polarizations, respectively. Finally, to demonstrate the application of this technology to a molecular film confined to a solid-liquid interface, visible ATR spectra of an adsorbed submono-layer of horse heart cytochrome e were acquired. A procedure to correct the wavegaide spectra for the wavelength dependence in ATR path length is described.
引用
收藏
页码:1751 / 1759
页数:9
相关论文
共 46 条
[1]   FIBEROPTIC CHEMICAL SENSORS [J].
ARNOLD, MA .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :A1015-A1025
[2]   Absence of surface exclusion in the first stage of lysozyme adsorption is driven through electrostatic self-assembly [J].
Ball, V ;
Ramsden, JJ .
JOURNAL OF PHYSICAL CHEMISTRY B, 1997, 101 (28) :5465-5469
[3]   SPECTROCHEMICAL MEASUREMENTS WITH MULTICHANNEL INTEGRATING DETECTORS [J].
BILHORN, RB ;
EPPERSON, PM ;
SWEEDLER, JV ;
DENTON, MB .
APPLIED SPECTROSCOPY, 1987, 41 (07) :1125-1136
[4]   OPTICAL WAVE-GUIDE TECHNIQUES FOR STRUCTURAL AND CHEMICAL-ANALYSIS IN THIN-FILM AND INTERFACIAL SYSTEMS [J].
BOHN, PW .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1987, 6 (09) :223-233
[5]  
Brash J. L., 1995, ACS SYM SER, V602, P1
[6]  
Brautigan D L, 1978, Methods Enzymol, V53, P128
[7]   ANALYSIS OF INPUT-GRATING COUPLERS HAVING FINITE LENGTHS [J].
BRAZAS, JC ;
LI, LF .
APPLIED OPTICS, 1995, 34 (19) :3786-3792
[8]  
CHARTIER G, 1981, INTEGRATED OPTICS PH, V91, P49
[9]   pH dependence of structural and functional properties of oxidized cytochrome c'' from Methylophilus methylotrophus [J].
Coletta, M ;
Costa, H ;
DeSanctis, G ;
Neri, F ;
Smulevich, G ;
Turner, DL ;
Santos, H .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1997, 272 (40) :24800-24804
[10]   WAVE-GUIDES AS CHEMICAL SENSORS [J].
DESSY, RE .
ANALYTICAL CHEMISTRY, 1989, 61 (19) :A1079-+