The use of an implantable force transducer to measure patellar tendon forces in goats

被引:73
作者
Korvick, DL [1 ]
Cummings, JF [1 ]
Grood, ES [1 ]
Holden, JP [1 ]
Feder, SM [1 ]
Butler, DL [1 ]
机构
[1] UNIV CINCINNATI,NOYES GIANNESTSRAS BIOMECH LABS ML048,DEPT AEROSP ENGN & ENGN MECH,CINCINNATI,OH 45221
关键词
tendon; biomechanics; transducers; goats animal; force measurements; patella tendon;
D O I
10.1016/0021-9290(95)00036-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Patellar tendon (PT) force was measured during activity with an implantable force transducer (IFT) in adult goats. PT force, vertical ground reaction force (VGRF) and the animal's speed were recorded for standing, walking and trotting. Following data collection, animals were euthanized and the IFT calibrated in vitro. Standing PT force averaged 207 N. Maximum PT force was approximately 800 N for walking and 1000 N for trotting and occurred at mid-stance. PT force dropped from 200 N at toe-off to 0 N by mid-swing. For each activity, the PT force increased with increases in VGRF. Maximum in vivo PT stress occurred during trotting and measured 29 MPa. This study demonstrates the IFT's usefulness in measuring tendon force directly.
引用
收藏
页码:557 / 561
页数:5
相关论文
共 21 条
[1]   DIRECT INVIVO TENDON FORCE MEASUREMENT SYSTEM [J].
AN, KN ;
BERGLUND, L ;
COONEY, WP ;
CHAO, EYS ;
KOVACEVIC, N .
JOURNAL OF BIOMECHANICS, 1990, 23 (12) :1269-1271
[2]   IN-VIVO TENDON TENSION AND BONE STRAIN MEASUREMENT AND CORRELATION [J].
BARNES, GRG ;
PINDER, DN .
JOURNAL OF BIOMECHANICS, 1974, 7 (01) :35-42
[3]   DESIGN AND PERFORMANCE OF A MODIFIED BUCKLE TRANSDUCER FOR THE MEASUREMENT OF LIGAMENT TENSION [J].
BARRY, D ;
AHMED, AM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (02) :149-152
[4]  
BIEWENER AA, 1988, J EXP BIOL, V140, P234
[5]  
BUTLER DL, 1984, J BIOMECH, V17, P57
[6]   A PHYSIOLOGICALLY BASED CRITERION OF MUSCLE FORCE PREDICTION IN LOCOMOTION [J].
CROWNINSHIELD, RD ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1981, 14 (11) :793-801
[7]  
CUMMINGS JF, 1991, T 37 ORTH RES SOC, V15, P601
[8]   RELATIONSHIP BETWEEN ANKLE MUSCLE AND JOINT KINETICS DURING THE STANCE PHASE OF LOCOMOTION IN THE CAT [J].
FOWLER, EG ;
GREGOR, RJ ;
HODGSON, JA ;
ROY, RR .
JOURNAL OF BIOMECHANICS, 1993, 26 (4-5) :465-483
[9]   IN-VITRO EVALUATION OF AN IMPLANTABLE FORCE TRANSDUCER (IFT) IN A PATELLAR TENDON MODEL [J].
GLOS, DL ;
BUTLER, DL ;
GROOD, ES ;
LEVY, MS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :335-343
[10]  
GOSLOW GE, 1981, J EXP BIOL, V94, P15