Rapid estimation of the accuracy of automatic blood pressure measuring devices (READ)

被引:6
作者
Naschitz, JE [1 ]
Gaitini, L [1 ]
Lowenstein, L [1 ]
Keren, D [1 ]
Tamir, A [1 ]
Yeshurun, D [1 ]
机构
[1] Bnai Zion Med Ctr, Dept Internal Med A, IL-31048 Haifa, Israel
关键词
validation; blood pressure measurement; tilt test;
D O I
10.1038/sj.jhh.1000841
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
We propose a rapid method for the evaluation of automatic blood pressure measurement devices (READ) in response to the claim to simplify the validation of those devices. The READ is based on numerous blood pressure (BP) measurements at rest and during a standardised postural challenge in a small number of subjects who exhibit a wide range of BPs. Automatic (AU) and mercury sphygmomanometric (MS) brachial BP were measured simultaneously in a blinded manner. An average of 30 measurements per patient were done in 10-min while in a supine position, followed by 30 min in head-up tilt and again supine for 10 min. Two Collin-8800 automated oscillometric devices were tested with the aid of the READ in 15 adults. The consistency of the MS standard was demonstrated by duplicate MS measurements showing minimal inter-observer differences consistent with class A of the British Hypertension Society (BHS) grading system. AD-to-MS differences of 447 measurements were mean systolic Delta BP = 1.1 +/- 11.4 mm Hg and mean diastolic Delta BP -13.36 +/- 8.9 mm Hg, classifying into category D of the BHS. Both tested instruments, each subject, each phase of the tilt test (supine I, tilt, supine II) and each mode of measurement (at 5-min intervals or continuously) equally qualified as 'D'. We conclude that the READ permitted us to identify quickly and at low expense a grossly inaccurate automatic BP measuring device. Further studies will show whether the READ can be efficient as a pre-validation test, post-validation test, and for assessment of ambulatory BP measuring devices.
引用
收藏
页码:443 / 447
页数:5
相关论文
共 12 条
  • [1] [Anonymous], 1987, AM NAT STAND EL AUT
  • [2] TRAINING AND CERTIFICATION OF BLOOD-PRESSURE OBSERVERS
    CURB, JD
    LABARTHE, DR
    COOPER, SP
    CUTTER, GR
    HAWKINS, CM
    [J]. HYPERTENSION, 1983, 5 (04) : 610 - 614
  • [3] CIRCULATORY RESPONSE TO POSTURAL CHANGE IN HEALTHY MALE-SUBJECTS IN RELATION TO AGE
    DAMBRINK, JHA
    WIELING, W
    [J]. CLINICAL SCIENCE, 1987, 72 (03) : 335 - 341
  • [4] DISCREPANCIES IN RECORDING SYSTOLIC BLOOD-PRESSURE OF ELDERLY PERSONS BY AMBULATORY BLOOD-PRESSURE MONITOR
    MILLER, ST
    ELAM, JT
    GRANEY, MJ
    APPLEGATE, WB
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1992, 5 (01) : 16 - 21
  • [5] Naschitz JE, 1996, J HUM HYPERTENS, V10, P369
  • [6] COMPARISON OF THE 10-MINUTE SUPINE 30-MINUTE TILT TEST WITH 24-HOUR AMBULATORY BLOOD-PRESSURE FOR THE DIAGNOSIS OF DIASTOLIC SYSTEMIC HYPERTENSION
    NASCHITZ, JE
    FEFER, F
    BOYER, S
    MAZOV, I
    SABO, E
    YESHURUN, D
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (05) : 366 - 369
  • [7] *NIH, 1997, NIH PUBL, P11
  • [8] OBrien E, 1995, J HYPERTENS, V13, P1235
  • [9] THE BRITISH-HYPERTENSION-SOCIETY PROTOCOL FOR THE EVALUATION OF AUTOMATED AND SEMIAUTOMATED BLOOD-PRESSURE MEASURING DEVICES WITH SPECIAL REFERENCE TO AMBULATORY SYSTEMS
    OBRIEN, E
    PETRIE, J
    LITTLER, W
    DESWIET, M
    PADFIELD, PL
    OMALLEY, K
    JAMIESON, M
    ALTMAN, D
    BLAND, M
    ATKINS, N
    [J]. JOURNAL OF HYPERTENSION, 1990, 8 (07) : 607 - 619
  • [10] Accuracy of an automated blood pressure device in stable inpatients -: Optimum vs routine use
    Shuler, CL
    Allison, N
    Holcomb, S
    Harlan, M
    McNeill, J
    Robinett, G
    Bagby, SP
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1998, 158 (07) : 714 - 721