Evaluation in mice of some iodinated melanoma imaging agents using cryosectioning and multi-wire proportional counting

被引:27
作者
Labarre, P [1 ]
Papon, J [1 ]
Moreau, MF [1 ]
Moins, N [1 ]
Veyre, A [1 ]
Madelmont, JC [1 ]
机构
[1] INSERM U484, F-63005 Clermont Ferrand, France
关键词
quantitative method; whole-body cryosectioning; melanoma imaging agents; radioiodinated benzamides; multi-wire proportional counter;
D O I
10.1007/s002590050416
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AMBIS 4000, a multi-wire proportional counter, was calibrated for iodine-125 measurements. The detector displayed a linear response over a wide dynamic range. Using whole-body mice cryosections, a linear relationship could be established between count rate per area (cpm/mm(2)) measured with the AMBIS 4000 detector and the count rate per gram (dpm/g) determined with an NaI(Tl) scintillation detector. A calibration curve could, thus be constructed. This new method allowed direct visual and quantitative evaluation of the biodistribution of a short series of I-125-labelled benzamides in melanoma-bearing mice. All the compounds studied showed good tumoral targeting ability. For one of them, ortho-hi (2-diethylaminoethyl)-4-iodobenzamide, liver and lung uptake decreased rapidly after dosing, making it a suitable tracer for scintigraphic detection of malignant melanoma.
引用
收藏
页码:494 / 498
页数:5
相关论文
共 16 条
[1]  
BRANDAU W, 1993, EUR J NUCL MED, V20, P238
[2]   AN ANALYSIS OF A MELANOMA EPIDEMIC [J].
BURTON, RC ;
COATES, MS ;
HERSEY, P ;
ROBERTS, G ;
CHETTY, MP ;
CHEN, S ;
HAYES, MH ;
HOWE, CG ;
ARMSTRONG, BK .
INTERNATIONAL JOURNAL OF CANCER, 1993, 55 (05) :765-770
[3]  
CODERRE JA, 1986, J NUCL MED, V27, P1157
[4]  
COHEN MB, 1988, J NUCL MED, V29, P1200
[5]  
Everaert H, 1997, J NUCL MED, V38, P870
[6]  
HOFFER P, 1980, J NUCL MED, V21, P394
[7]   VALIDITY OF TISSUE PASTE STANDARDS FOR QUANTITATIVE WHOLE-BODY AUTORADIOGRAPHY USING SHORT-LIVED RADIONUCLIDES [J].
ITO, T ;
BRILL, AB .
APPLIED RADIATION AND ISOTOPES, 1990, 41 (07) :661-667
[8]   AN IMPROVED SYNTHESIS OF [I-125] N-(DIETHYLAMINOETHYL)-4-IODOBENZAMIDE - A POTENTIAL LIGAND FOR IMAGING MALIGNANT-MELANOMA [J].
JOHN, CS ;
SAGA, T ;
KINUYA, S ;
LE, N ;
JEONG, JM ;
PAIK, CH ;
REBA, RC ;
VARMA, VM ;
MCAFEE, JG .
NUCLEAR MEDICINE AND BIOLOGY, 1993, 20 (01) :75-79
[9]   A new quantitative method to evaluate the biodistribution of a radiolabelled tracer for melanoma using whole-body cryosectioning and a gaseous detector: comparison with conventional tissue combustion technology [J].
Labarre, P ;
Papon, J ;
Moreau, MF ;
Madelmont, JC ;
Veyre, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (02) :109-114
[10]  
MICHELOT JM, 1991, J NUCL MED, V32, P1573