Utility of pulse oximetry in the detection of arterial hypoxemia in liver transplant candidates

被引:72
作者
Abrams, GA [1 ]
Sanders, MK [1 ]
Fallon, MB [1 ]
机构
[1] Univ Alabama Birmingham, Birmingham Liver Ctr, Dept Internal Med, Birmingham, AL 35294 USA
关键词
D O I
10.1053/jlts.2002.32252
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Hepatopulmonary syndrome, arterial hypoxemia caused by intrapulmonary vasodilatation, occurs in approximately 10% of patients with cirrhosis. The severity of hypoxemia affects liver transplant candidacy and is associated with increased morbidity and mortality posttransplantation. Screening guidelines for detecting the presence of arterial hypoxemia do not exist. The aim of this study is to investigate the accuracy and utility of pulse oximetry in the detection of hypoxemia (PaO2 < 70 min Hg) in patients with cirrhosis. Two hundred prospective liver transplant candidates were compared with 94 controls. Arterial oxyhemoglobin saturation was obtained by pulse oximetry (SpO(2)) and compared with simultaneous arterial blood gas (ABG) oxyhemoglobin values (SaO(2), bias = the difference). PaO2, carboxyhemoglobin, methemoglobin, and routine clinical and biochemical parameters were investigated to account for the bias. SpO(2) overestimated SaO(2) in 98% of patients with cirrhosis (mean bias, 3.37%; range, -1% to 10%). Forty-four percent of patients with cirrhosis and controls had a bias of 4% or greater. No clinical or biochemical parameters of cirrhosis accounted for the overestimation of pulse oximetry. Twenty-five subjects with cirrhosis were hypoxemic, and an SpO(2) of 97% or less showed a sensitivity of 96% and a positive likelihood ratio of 3.9 for detecting hypoxemia. An SpO(2) of 94% or less detected all subjects with an arterial PaO2 less than 60 mm Hg. Pulse oximetry significantly overestimates arterial oxygenation, and the inaccuracy is not influenced by liver disease. Nevertheless, pulse oximetry can be a useful screening tool to detect arterial hypoxemia in patients with cirrhosis, but a higher threshold for obtaining an ABG must be used.
引用
收藏
页码:391 / 396
页数:6
相关论文
共 18 条
[1]   DIAGNOSTIC UTILITY OF CONTRAST ECHOCARDIOGRAPHY AND LUNG PERFUSION SCAN IN PATIENTS WITH HEPATOPULMONARY SYNDROME [J].
ABRAMS, GA ;
JAFFE, CC ;
HOFFER, PB ;
BINDER, HJ ;
FALLON, MB .
GASTROENTEROLOGY, 1995, 109 (04) :1283-1288
[2]   Use of macroaggregated albumin lung perfusion scan to diagnose hepatopulmonary syndrome: A new approach [J].
Abrams, GA ;
Nanda, NC ;
Dubovsky, EV ;
Krowka, MJ ;
Fallon, MB .
GASTROENTEROLOGY, 1998, 114 (02) :305-310
[3]   LUNG-FUNCTION TESTING - SELECTION OF REFERENCE VALUES AND INTERPRETATIVE STRATEGIES [J].
不详 .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 144 (05) :1202-1218
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
HOURANI JM, 1991, AM J MED, V90, P693
[6]   Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults [J].
Jensen, LA ;
Onyskiw, JE ;
Prasad, NGN .
HEART & LUNG, 1998, 27 (06) :387-408
[7]   Hepatopulmonary syndrome with progressive hypoxemia as an indication for liver transplantation: Case reports and literature review [J].
Krowka, MJ ;
Porayko, MK ;
Plevak, DJ ;
Pappas, SC ;
Steers, JL ;
Krom, RAF ;
Wiesner, RH .
MAYO CLINIC PROCEEDINGS, 1997, 72 (01) :44-53
[8]   A PROSPECTIVE-STUDY OF PULMONARY-FUNCTION AND GAS-EXCHANGE FOLLOWING LIVER-TRANSPLANTATION [J].
KROWKA, MJ ;
DICKSON, ER ;
WIESNER, RH ;
KROM, RAF ;
ATKINSON, B ;
CORTESE, DA .
CHEST, 1992, 102 (04) :1161-1166
[9]   The hepatopulmonary syndrome - Effect of liver transplantation [J].
Lange, PA ;
Stoller, JK .
CLINICS IN CHEST MEDICINE, 1996, 17 (01) :115-+
[10]   EFFECTS OF ANEMIA ON PULSE OXIMETRY AND CONTINUOUS MIXED VENOUS HEMOGLOBIN SATURATION MONITORING IN DOGS [J].
LEE, S ;
TREMPER, KK ;
BARKER, SJ .
ANESTHESIOLOGY, 1991, 75 (01) :118-122