Screen-printed amperometric biosensors for the rapid measurement of L- and D-amino acids

被引:89
作者
Sarkar, P [1 ]
Tothill, IE [1 ]
Setford, SJ [1 ]
Turner, APF [1 ]
机构
[1] Cranfield Univ, Cranfield Biotechnol Ctr, Cranfield MK43 0AL, Beds, England
关键词
D O I
10.1039/a901404g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Screen-printed three-electrode amperometric sensors incorporating L- and/or D-amino acid oxidase for the general purpose measurement of L- or D-amino acids is described. The working electrode incorporates rhodinised carbon, to facilitate hydrogen peroxide oxidation at a decreased operating potential, and immobilised enzyme. The devices responded to all 20 common L-amino acids and all of the D-amino acids examined, the exceptions being L- and D-proline. Linear response profiles were observed for L-leucine, L-glycine and L-phenylalanine with limits of detection of 0.47, 0.15 and 0.20 mM respectively. The devices were reproducible and exhibited stability over a 56 d test period. The biosensor compares favourably with a standard photometric amino acid test and was used to monitor milk ageing effects, The assay is cheap, simple to perform and rapid, requiring only buffer-electrolyte and a small sample volume.
引用
收藏
页码:865 / 870
页数:6
相关论文
共 32 条
[1]  
Albery WJ, 1996, J APPL ELECTROCHEM, V26, P243
[2]  
BARMAN TE, 1969, ENZYME HDB, V1, P178
[3]  
BENNETTO HP, 1987, Patent No. 0247850
[4]   AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF OXIDASES IN A PRUSSIAN BLUE FILM BY ELECTROCHEMICAL CODEPOSITION [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :429-436
[5]   A BIOSENSOR FOR L-AMINO-ACIDS USING POLYTYRAMINE FOR ENZYME IMMOBILIZATION [J].
COOPER, JC ;
SCHUBERT, F .
ELECTROANALYSIS, 1994, 6 (11-12) :957-961
[6]   MEDIATED AMPEROMETRIC BIOSENSORS FOR D-GALACTOSE, GLYCOLATE AND L-AMINO-ACIDS BASED ON A FERROCENE-MODIFIED CARBON PASTE ELECTRODE [J].
DICKS, JM ;
ASTON, WJ ;
DAVIS, G ;
TURNER, APF .
ANALYTICA CHIMICA ACTA, 1986, 182 :103-112
[7]   REAGENTLESS CHEMICALLY-MODIFIED CARBON-PASTE ELECTRODE BASED ON A PHENOTHIAZINE POLYMER DERIVATIVE AND YEAST ALCOHOL-DEHYDROGENASE FOR THE ANALYSIS OF ETHANOL [J].
DOMINGUEZ, E ;
LAN, HL ;
OKAMOTO, Y ;
HALE, PD ;
SKOTHEIM, TA ;
GORTON, L ;
HAHNHAGERDAL, B .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (3-4) :229-237
[8]   D-AMINO ACIDS IN MILK AS RELATED TO HEAT-TREATMENTS AND BACTERIAL-ACTIVITY [J].
GANDOLFI, I ;
PALLA, G ;
DELPRATO, L ;
DENISCO, F ;
MARCHELLI, R ;
SALVADORI, C .
JOURNAL OF FOOD SCIENCE, 1992, 57 (02) :377-379
[9]   HOMOVANILLIC ACID AS A FLUOROMETRIC SUBSTRATE FOR OXIDATIVE ENZYMES - ANALYTICAL APPLICATIONS OF PEROXIDASE GLUCOSE OXIDASE AND XANTHINE OXIDASE SYSTEMS [J].
GUILBAULT, GG ;
BRIGNAC, P ;
ZIMMER, M .
ANALYTICAL CHEMISTRY, 1968, 40 (01) :190-+
[10]   ELECTRODE FOR DETERMINATION OF AMINO ACIDS [J].
GUILBAULT, GG ;
HRABANKOVA, E .
ANALYTICAL CHEMISTRY, 1970, 42 (14) :1779-+