The development of a full-custom electronic acquisition system designed for readout of large-area active matrix hat-panel imaging arrays is reported. The arrays, which comprise two-dimensional matrices of pixels utilizing amorphous silicon thin-him transistors, are themselves under development for a wide variety of X-ray imaging applications. The acquisition system was specifically designed to facilitate detailed, quantitative investigations of the properties of these novel imaging arrays and contains significant enhancements compared to a previously developed acquisition system. These enhancements include pipelined preamplifier circuits to allow faster readout speed, expanded addressing capabilities allowing a maximum of 4096 array data lines, and on-board summing of image frames. The values of many acquisition system parameters, including timings and voltages, may be specified and downloaded from a host computer. Once acquisition is enabled, the system operates asynchronously of its host computer. The system allows image capture in both radiographic mode (corresponding to the capture of individual X-ray images), and fluoroscopic mode (corresponding to the capture of a continual series of X-ray images). A detailed description of the system architecture and the underlying motivations for the design is reported in this paper. (C) 1999 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:273 / 284
页数:12
相关论文
共 8 条
[1]   Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation [J].
Antonuk, LE ;
ElMohri, Y ;
Siewerdsen, JH ;
Yorkston, J ;
Huang, W ;
Scarpine, VE ;
Street, RA .
MEDICAL PHYSICS, 1997, 24 (01) :51-70
[2]   Initial performance evaluation of an indirect-detection, active matrix flat-panel imager (AMFPI) prototype for megavoltage imaging [J].
Antonuk, LE ;
El-Mohri, Y ;
Huang, WD ;
Jee, KW ;
Siewerdsen, JH ;
Maolinbay, M ;
Scarpine, VE ;
Sandler, H ;
Yorkston, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02) :437-454
[3]   A large-area, 97 μm pitch, indirect-detection, active matrix, flat-panel imager (AMFPI) [J].
Antonuk, LE ;
El-Mohri, Y ;
Hall, A ;
Jee, KW ;
Maolinbay, M ;
Nassif, SC ;
Rong, XJ ;
Siewerdsen, JH ;
Zhao, QH ;
Weisfield, RL .
PHYSICS OF MEDICAL IMAGING, 1998, 3336 :2-13
[4]   THIN-FILM, FLAT-PANEL, COMPOSITE IMAGERS FOR PROJECTION AND TOMOGRAPHIC IMAGING [J].
ANTONUK, LE ;
BOUDRY, J ;
HUANG, WD ;
LAM, KL ;
MORTON, EJ ;
TENHAKEN, RK ;
YORKSTON, J ;
CLINTHORNE, NH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (03) :482-490
[5]   A DATA-ACQUISITION SYSTEM FOR FLAT-PANEL IMAGING ARRAYS [J].
MORTON, EJ ;
ANTONUK, LE ;
BERRY, JE ;
HUANG, W ;
MODY, P ;
YORKSTON, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1150-1154
[6]   Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology [J].
Siewerdsen, JH ;
Antonuk, LE ;
ElMohri, Y ;
Yorkston, J ;
Huang, W ;
Boudry, JM ;
Cunningham, IA .
MEDICAL PHYSICS, 1997, 24 (01) :71-89
[7]  
STREET RA, 1997, P MAT RES SOC, V487, P399
[8]   Digital radiology using active matrix readout of amorphous selenium: Construction and evaluation of a prototype real-time detector [J].
Zhao, W ;
Blevis, I ;
Germann, S ;
Rowlands, JA ;
Waechter, D ;
Huang, ZS .
MEDICAL PHYSICS, 1997, 24 (12) :1834-1843