Position and orientation in space of bones during movement: Experimental artefacts

被引:533
作者
Cappozzo, A
Catani, F
Leardini, A
Benedetti, MG
DellaCroce, U
机构
[1] UNIV SASSARI,IST FISIOL UMANA,I-07100 SASSARI,ITALY
[2] IST ORTOPED RIZZOLI,LAB BIOMECCAN,BOLOGNA,ITALY
关键词
movement analysis; stereophotogrammetry; skin movement artefacts;
D O I
10.1016/0268-0033(95)00046-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
This paper deals with the experimental problems related to the reconstruction of the position and orientation of the lower limb bones in space during the execution of locomotion and physical exercises. The inaccuracies associated with the relative movement between markers and underlying bone are analysed. Quantitative information regarding this movement was collected by making experiments on subjects who had suffered fractures and were wearing either femoral or tibial external fixators. These latter devices provided frames that were reliably rigid with the bone involved, and hence the possibility of assessing the relative movement between markers mounted on the skin and this bone, Anatomical frames associated with thigh and shank were reconstructed using technical frames based on different clusters of skin markers and their rotation with respect to the relevant bone evaluated. Marker movement was also assessed in subjects with intact musculoskeletal structures using digital videofluoroscopy.
引用
收藏
页码:90 / 100
页数:11
相关论文
共 21 条
[1]
BENEDETTI MG, 1994, ANATOMICAL LANDMARK
[2]
CAPPELLO A, 1994, P 3 INT S 3 D AN HUM, P15
[3]
GAIT ANALYSIS METHODOLOGY [J].
CAPPOZZO, A .
HUMAN MOVEMENT SCIENCE, 1984, 3 (1-2) :27-50
[4]
3-DIMENSIONAL ANALYSIS OF HUMAN WALKING - EXPERIMENTAL METHODS AND ASSOCIATED ARTIFACTS [J].
CAPPOZZO, A .
HUMAN MOVEMENT SCIENCE, 1991, 10 (05) :589-602
[5]
CAPPOZZO A, 1994, PGD LEXICON
[6]
CAPPOZZO A, 1995, CLIN BIOMECH, V4, P171
[7]
A SOLIDIFICATION PROCEDURE TO FACILITATE KINEMATIC ANALYSES BASED ON VIDEO SYSTEM DATA [J].
CHEZE, L ;
FREGLY, BJ ;
DIMNET, J .
JOURNAL OF BIOMECHANICS, 1995, 28 (07) :879-884
[8]
TECHNIQUE FOR THE EVALUATION OF DERIVATIVES FROM NOISY BIOMECHANICAL DISPLACEMENT DATA USING A MODEL-BASED BANDWIDTH-SELECTION PROCEDURE [J].
DAMICO, M ;
FERRIGNO, G .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (05) :407-415
[9]
A JOINT COORDINATE SYSTEM FOR THE CLINICAL DESCRIPTION OF 3-DIMENSIONAL MOTIONS - APPLICATION TO THE KNEE [J].
GROOD, ES ;
SUNTAY, WJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02) :136-144
[10]
Karlsson D, 1994, P 3 INT S 3D AN HUM, P27