In vitro human monocyte response to wear particles of titanium alloy containing vanadium or niobium

被引:136
作者
Rogers, SD
Howie, DW
Graves, SE
Pearcy, MJ
Haynes, DR
机构
[1] ROYAL ADELAIDE HOSP,DEPT ORTHOPAED & TRAUMA,ADELAIDE,SA 5000,AUSTRALIA
[2] UNIV ADELAIDE,DEPT PATHOL,ADELAIDE,SA 5005,AUSTRALIA
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1997年 / 79B卷 / 02期
关键词
D O I
10.1302/0301-620X.79B2.7192
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Our aim was to determine whether in vitro studies would detect differences in the cellular response to wear particles of two titanium alloys commonly used in the manufacture of joint replacement prostheses. Particles were of the order of 1 mu m in diameter representative of those found adjacent to failed prostheses. Exposure of human monocytes to titanium 6-aluminium 4- vanadium (TiAlV) at concentrations of 4 x 10(7) particles/ml produced a mean prostaglandin E(2) release of 2627.6 pM; this was significantly higher than the 317.4 pM induced by titanium 7-niobium alloy (TiAlNb) particles Commercially-pure titanium particles induced a release of 347.8 pM. In addition, TiAlV stimulated significantly more release of the other cell mediators, interleukin-1, tumour necrosis factor and interleukin-6, At lower concentrations of particles there was less mediator release and less obvious differences between materials. None of the materials caused significant toxicity, The levels of inflammatory mediators released by phagocytic cells in response to wear particles may influence the amount of periprosthetic bone loss, Our findings have shown that in vitro studies can detect differences in cellular response induced by particles of similar titanium alloys in common clinical use, although in vivo studies have shown little difference, While in vitro studies should not be used as the only form of assessment, they must be considered when assessing the relative biocompatibility of different implant materials.
引用
收藏
页码:311 / 315
页数:5
相关论文
共 37 条
[1]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]  
ANDREW SM, 1993, T 39 ANN M ORTH RES, V18, P243
[3]  
[Anonymous], BIOL BIOMECHANICAL P
[4]  
ASTM, 1980, ANN BOOK ASTM STA 46
[5]  
Bennett NE, 1991, T ORTHOP RES SOC, V16, P188
[6]   METALLOSIS ASSOCIATED WITH A STABLE TITANIUM-ALLOY FEMORAL COMPONENT IN TOTAL HIP-REPLACEMENT - A CASE-REPORT [J].
BLACK, J ;
SHERK, H ;
BONINI, J ;
ROSTOKER, WR ;
SCHAJOWICZ, F ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (01) :126-130
[7]  
CHIBA J, 1994, CLIN ORTHOP RELAT R, V300, P304
[8]  
Cila E, 1994, J Arthroplasty, V9, P67, DOI 10.1016/0883-5403(94)90139-2
[9]  
DORR LD, 1990, CLIN ORTHOP RELAT R, V261, P82
[10]  
FRONDOZA C, 1994, T 40 ANN M ORTH RES, V19, P154