Three-dimensional respiratory-gated MR angiography of coronary arteries: Comparison with conventional coronary angiography

被引:133
作者
Post, JC
vanRossum, AC
Hofman, MBM
Valk, J
Visser, CA
机构
[1] FREE UNIV AMSTERDAM HOSP,DEPT CLIN PHYS & ENGN,1081 HV AMSTERDAM,NETHERLANDS
[2] FREE UNIV AMSTERDAM HOSP,DEPT RADIOL,1081 HV AMSTERDAM,NETHERLANDS
关键词
D O I
10.2214/ajr.166.6.8633453
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. MR coronary angiography is most often performed using two-dimensional techniques. Although three-dimensional (3D) acquisitions do have important advantages, they take too long for a single breath-hold and are thus susceptible to respiratory motion artifacts. The purpose of this study was to investigate the accuracy of a unique respiratory-gated 3D MR angiographic technique in identifying the proximal coronary arteries in patients suspected of having coronary artery disease. In addition, we investigated the capability of this technique to detect proximal stenoses. SUBJECTS AND METHODS, We performed a prospective blinded study in 20 patients who were referred for conventional coronary angiography. A cardiac-gated 3D gradient-echo sequence with fat suppression was used. Retrospective respiratory gating was performed using navigator echoes of the diaphragm position, Using multiplanar reformatting, two independent readers blindly analyzed the data sets for visualization of major coronary arteries, lengths of imaged segments, and detection of significant stenoses (>50% occlusion of the luminal diameter by conventional angiography). RESULTS. Seventy-seven of 80 (96%) coronary arteries were positively identified, In one patient, an anomalous coronary anatomy was readily identified and confirmed by conventional angiography. The average lengths of the imaged segments of the right, left main, left anterior descending, and left circumflex coronary arteries were 58 +/-13 mm, 9 +/- 5 mm, 59 +/- 16 mm, and 24 +/- 10 mm, respectively. Overall sensitivity for the detection of stenoses was low (38%), with a specificity of 95%. Interobserver agreement was 0.92, with a kappa value of 0.65. CONCLUSION. Respiratory-gated 3D MR angiography allows accurate identification of proximal coronary arteries and may be valuable for 3D imaging of coronary anomalies, Further technical improvements are required to enhance the value of the technique in detecting stenoses.
引用
收藏
页码:1399 / 1404
页数:6
相关论文
共 25 条
[1]  
CASSIDY M, 1989, AM J CARDIAC IMAGING, V3, P100
[2]  
CHIEN D, 1994, P SOC MAGN RES 1994, P502
[3]   NMR ANGIOGRAPHY OF CORONARY VESSELS WITH 2-D PLANAR IMAGE SCANNING [J].
CHO, ZH ;
MUN, CW ;
FRIEDENBERG, RM .
MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (01) :134-143
[4]   LUMEN DIAMETER OF NORMAL HUMAN CORONARY-ARTERIES - INFLUENCE OF AGE, SEX, ANATOMIC VARIATION, AND LEFT-VENTRICULAR HYPERTROPHY OR DILATION [J].
DODGE, JT ;
BROWN, BG ;
BOLSON, EL ;
DODGE, HT .
CIRCULATION, 1992, 86 (01) :232-246
[5]   2-DIMENSIONAL CORONARY MR-ANGIOGRAPHY - ANALYSIS OF INITIAL CLINICAL-RESULTS [J].
DUERINCKX, AJ ;
URMAN, MK .
RADIOLOGY, 1994, 193 (03) :731-738
[6]   A METHOD OF CORONARY MR ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
DARROW, RD ;
ADAMS, WJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :705-710
[7]   CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY [J].
EDELMAN, RR ;
MANNING, WJ ;
BURSTEIN, D ;
PAULIN, S .
RADIOLOGY, 1991, 181 (03) :641-643
[8]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[9]  
HOFMAN MBM, 1995, J COMPUT ASSIST TOMO, V19, P56
[10]   CORONARY ARTERIOGRAPHY 1984-1987 - A REPORT OF THE REGISTRY OF THE SOCIETY FOR CARDIAC ANGIOGRAPHY AND INTERVENTIONS .1. RESULTS AND COMPLICATIONS [J].
JOHNSON, LW ;
LOZNER, EC ;
JOHNSON, S ;
KRONE, R ;
PICHARD, AD ;
VETROVEC, GW ;
NOTO, TJ .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1989, 17 (01) :5-10