Ultrasound backscatter and attenuation in human liver with diffuse disease

被引:132
作者
Lu, ZF
Zagzebski, JA
Lee, FT
机构
[1] Columbia Univ, Dept Radiol, New York, NY 10032 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
关键词
ultrasound; attenuation coefficient; backscatter coefficient; phantoms; liver; diffuse liver disease; fatty liver; cirrhosis;
D O I
10.1016/S0301-5629(99)00055-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound backscatter and attenuation in the liver were measured in patients with diffuse liver disease and in 35 volunteers who had no history of liver ailments. Measurements were done using radiofrequency (RF) echo signals derived from a clinical scanner; a reference phantom was scanned to account for effects of gain, transmit-receive frequency response and transducer beam patterns on echo data. The mean backscatter coefficient at 3 MHz in livers of 7 patients with fatty infiltration was 6.8 x 10(-3) cm(-1)sr(-1) compared to a mean of 0.5 x 10(-3) cm(-1)sr(-1) in healthy patients. Mean attenuation at 3 MHz was 2.54 dB/cm in fatty livers compared to 1.66 dB/cm in healthy patients, A total of 7 patients with end-stage liver disease (cirrhosis) had attenuation values similar to those in the healthy group, and their mean liver backscatter was somewhat greater than the mean backscatter for healthy livers. Quantitating both backscatter and attenuation should be considered for detecting fatty infiltration; additional processing methods are needed to differentiate cirrhotic changes on the basis of acoustic signals. (C) 1999 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1047 / 1054
页数:8
相关论文
共 48 条
[1]   INFLUENCE OF PATHOLOGICAL STATE ON THE ACOUSTIC ATTENUATION COEFFICIENT SLOPE OF LIVER [J].
AFSCHRIFT, M ;
CUVELIER, C ;
RINGOIR, S ;
BARBIER, F .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (03) :135-139
[2]   ACOUSTIC PROPERTIES OF NORMAL AND CANCEROUS HUMAN-LIVER .1. DEPENDENCE ON PATHOLOGICAL CONDITION [J].
BAMBER, JC ;
HILL, CR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1981, 7 (02) :121-&
[3]   BACKSCATTER COEFFICIENT IMAGING USING A CLINICAL SCANNER [J].
BOOTE, EJ ;
ZAGZEBSKI, JA ;
MADSEN, EL .
MEDICAL PHYSICS, 1992, 19 (05) :1145-1152
[4]   NEW ULTRASOUND TISSUE-EQUIVALENT MATERIAL [J].
BURLEW, MM ;
MADSEN, EL ;
ZAGZEBSKI, JA ;
BANJAVIC, RA ;
SUM, SW .
RADIOLOGY, 1980, 134 (02) :517-520
[5]  
Castro MA, 1996, J REPROD MED, V41, P839
[6]   CLINICAL SOUND SPEED MEASUREMENT IN LIVER AND SPLEEN INVIVO [J].
CHEN, CF ;
ROBINSON, DE ;
WILSON, LS ;
GRIFFITHS, KA ;
MANOHARAN, A ;
DOUST, BD .
ULTRASONIC IMAGING, 1987, 9 (04) :221-235
[7]   TESTS OF BACKSCATTER COEFFICIENT MEASUREMENT USING BROAD-BAND PULSES [J].
CHEN, JF ;
ZAGZEBSKI, JA ;
MADSEN, EL .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (05) :603-607
[8]   INVITRO ESTIMATION OF ACOUSTIC PARAMETERS OF THE LIVER AND CORRELATIONS WITH HISTOLOGY [J].
CLOOSTERMANS, MJTM ;
MOL, H ;
VERHOEF, WA ;
THIJSSEN, JM ;
KUBAT, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (01) :39-51
[9]  
CROKETT HC, 1994, SURG LAPAROSC ENDOSC, V4, P230
[10]   PARADOXICAL LACK OF ULTRASOUND ATTENUATION WITH GROSS FATTY CHANGE IN THE LIVER [J].
DAVIES, RJ ;
SAVERYMUTTU, SH ;
FALLOWFIELD, M ;
JOSEPH, AEA .
CLINICAL RADIOLOGY, 1991, 43 (06) :393-396